Induced astigmatism after photorefractive keratectomy.

机译:屈光性角膜切除术后诱发散光。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To retrospectively analyze a group of patients to determine whether their induced astigmatism was caused by asymmetry in the laser beam, asymmetry in ablation rates, or wound healing in different corneal meridians. SETTING: Single-center physician office. METHODS: In this study, 146 eyes of 116 patients who had photorefractive keratectomy (PRK) for myopia with the Apex laser (Summit Technology) were retrospectively identified. In 28 eyes, the patient's chair had been rotated 90 degrees from its usual position under the laser. The vector-summated mean change in astigmatism in eyes with the chair rotated 90 degrees was compared with that in a group of control eyes in which the chair was in the usual position. RESULTS: The vector-summated mean change in the control eyes was 0.30 diopter (D) at 83 degrees. Forty-eight of 113 eyes (42.5%) had induced with-the-rule (WTR) astigmatism, and 14 of 113 eyes (12.4%) had induced against-the-rule (ATR) astigmatism. In the eyes in which the chair was rotated 90 degrees, vector-summated mean change was 0.10 D at 13 degrees (P < .0005). One of 27 eyes (3.7%) had induced WTR astigmatism, and 13 of 27 eyes (48.1%) had induced ATR astigmatism (P < .001, chi-square). CONCLUSION: Astigmatism induced by myopic PRK with the Apex laser was small. The axis of induced astigmatism rotated 90 degrees when the patient's chair was rotated, implying that it is inhomogeneities in the beam rather than meridional asymmetry in ablation rates or wound healing that are responsible for induced astigmatism.
机译:目的:回顾性分析一组患者,以确定其诱发的散光是由激光束不对称,消融率不对称或不同角膜子午线的伤口愈合引起的。地点:单中心医师办公室。方法:本研究回顾性分析了116例使用Apex激光(Summit Technology)对近视进行光折射性角膜切除术(PRK)的患者的146眼。在28只眼睛中,患者的椅子在激光照射下已从其通常位置旋转了90度。将椅子旋转90度时眼睛的矢量求和的平均散光变化与椅子处于通常位置的一组对照组眼睛的矢量变化进行了比较。结果:对照眼的矢量求和平均变化在83度为0.30屈光度(D)。 113眼中有48眼(42.5%)诱发了规则性(WTR)散光,而113眼中的14眼(12.4%)引起了规则性(ATR)散光。在椅子旋转90度的眼睛中,矢量求和的平均变化在13度时为0.10 D(P <.0005)。 27眼中的一只(3.7%)诱发了WTR散光,27眼中的13只眼(48.1%)诱发了ATR散光(P <.001,卡方)。结论:Apex激光引起的近视PRK引起的散光很小。当患者的椅子旋转时,诱发散光的轴旋转了90度,这说明造成散光的原因在于光束的不均匀性而不是消融率或伤口愈合的子午线不对称。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号