OBJECTIVE-To compare three continuous glucose monitoring (CGM) devices in subjects with type 1 diabetes under closed-loop blood glucose (BG) control. RESEARCH DESIGN AND METHODS-Six subjects with type 1 diabetes (age 52 ± 14 years, diabetes duration 32 ± 14 years) each participated in two 51-h closed-loop BG control experiments in the hospital. Venous plasma glucose (PG) measurements (GlucoScout, International Biomedical) obtained every 15 min (2,360 values) were paired in time with corresponding CGM glucose (CGMG) measurements obtained from three CGM devices, the Navigator (Abbott Diabetes Care), the Seven Plus (DexCom), and the Guardian (Medtronic), worn simultaneously by each subject. Errors in paired PG-CGMG measurements and data reporting percentages were obtained for each CGM device. RESULTS-The Navigator had the best overall accuracy, with an aggregate mean absolute relative difference (MARD) of all paired points of 11.8 ± 11.1% and an average MARD across all 12 experiments of 11.8 ± 3.8%. The Seven Plus and Guardian produced aggregate MARDs of all paired points of 16.5 ± 17.8% and 20.3 ± 18.0%, respectively, and average MARDs across all 12 experiments of 16.5 ± 6.7% and 20.2 ± 6.8%, respectively. Data reporting percentages, a measure of reliability, were 76% for the Seven Plus and nearly 100% for the Navigator and Guardian. CONCLUSIONS-A comprehensive head-to-head-to-head comparison of three CGM devices for BG values from 36 to 563 mg/dL revealed marked differences in performance characteristics that include accuracy, precision, and reliability. The Navigator outperformed the other two in these areas.
机译:目的-比较在闭环血糖(BG)控制下的1型糖尿病患者的三种连续血糖监测(CGM)设备。研究设计和方法-六名1型糖尿病患者(年龄52±14岁,糖尿病病程32±14岁)均参加了医院的两个51小时闭环BG对照实验。每15分钟(2,360个值)获得的静脉血浆葡萄糖(PG)测量值(GlucoScout,International Biomedical)与从三个CGM设备,导航器(Abbott Diabetes Care),Seven Plus仪器获得的相应CGM葡萄糖(CGMG)测量值及时配对(DexCom)和《卫报》(Medtronic),每个对象同时佩戴。对于每个CGM设备,都获得了成对的PG-CGMG测量值和数据报告百分比的误差。结果-Navigator的整体精度最高,所有配对点的总平均绝对相对差(MARD)为11.8±11.1%,所有12个实验的平均MARD为11.8±3.8%。 Seven Plus和Guardian生成的所有配对点的累计MARD分别为16.5±17.8%和20.3±18.0%,而所有12个实验的平均MARD分别为16.5±6.7%和20.2±6.8%。数据报告百分比(衡量可靠性的标准)对于Seven Plus为76%,对于Navigator和Guardian为近100%。结论-三种CGM设备的BG值从36到563 mg / dL进行了全面的头对头比较,显示出性能特征上的显着差异,包括准确度,精确度和可靠性。在这些方面,导航器的性能优于其他两个。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号