首页> 外文期刊>Water Science and Technology >Impact of anti-scalant on fouling of reverse osmosis membranes in reclamation of secondary effluent
【24h】

Impact of anti-scalant on fouling of reverse osmosis membranes in reclamation of secondary effluent

机译:防垢剂对二次废水回收利用中反渗透膜结垢的影响

获取原文
获取原文并翻译 | 示例
           

摘要

The objective of the study was to evaluate the impact of anti-scalant on fouling of reverse osmosis (RO) membranes in reclamation of secondary effluent which was produced by a conventional activated sludge process at Kranji Water Reclamation Plant with the capacity of 151,000m3/d. The study was carried out using a RO pilot plant with the capacity of 2.4m3/h. The RO plant was in 2:1 configuration and was operated at 75% recovery and at membrane flux of 17 lm22 h21. Pilot trials were conducted with and without anti-scalant. Compositions of feed and concentrate streams were analyzed and the pilot data were normalized. The results of the study showed that the plant operation was stable during the first few days after stopping dosage of anti-scalant but after 3–6 days of operation the membranes were fouled. The time lag effect of anti-scalant without dosage was not reported previously and could be potentially beneficial to save chemicals. The membrane fouling was more serious at the second stage due to the formation of calcium phosphate scale when the pilot plant was operated without anti-scalant. The flux of fouled membranes could be completely recovered after clean-in-place (CIP) with citric acid, indicating that scaling dominated the fouling of the RO membranes. These findings in the study could be applied to select an appropriate anti-scalant for prevention from formation of calcium phosphate scale in the RO operation.
机译:这项研究的目的是评估在Kranji水回收厂采用常规活性污泥工艺生产的二次废水回收中,防垢剂对反渗透(RO)膜结垢的影响。 。该研究是使用容量为2.4m3 / h的反渗透中试装置进行的。反渗透装置为2:1配置,回收率为75%,膜通量为17 lm22 h21。在有和没有防垢剂的情况下进行了试验。分析了进料流和精矿流的组成,并对中试数据进行了标准化。研究结果表明,在停止使用防垢剂后的头几天,工厂的运行稳定,但在运行3-6天后,膜被弄脏了。以前没有报道不添加抗垢剂的时滞效应,可能对节省化学品有潜在的好处。由于在不使用防垢剂的情况下运行中试工厂时,由于磷酸钙结垢的形成,第二阶段的膜结垢更为严重。在用柠檬酸进行就地清洗(CIP)后,污垢膜的通量可以完全恢复,这表明结垢主导了RO膜的结垢。该研究中的这些发现可用于选择合适的防垢剂,以防止在反渗透操作中形成磷酸钙垢。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号