首页> 外文期刊>The Laryngoscope: A Medical Journal for Clinical and Research Contributions in Otolaryngology, Head and Neck Medicine and Surgery, Facial Plastic and Reconstructive Surgery .. >Tonsillectomy in children: a five-factor analysis among three techniques--reporting upon clinical results, anesthesia time, surgery time, bleeding, and cost.
【24h】

Tonsillectomy in children: a five-factor analysis among three techniques--reporting upon clinical results, anesthesia time, surgery time, bleeding, and cost.

机译:儿童扁桃体切除术:三种技术中的五因素分析-报告临床结果,麻醉时间,手术时间,出血和费用。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVES: Improved technology claims better clinical results for adenotonsillectomy (T&A) in children, and promoters of each technique announce many virtues over one another, year after year. However, cost remains one variable that is not always thoroughly addressed. In this study, monopolar cautery (MPC) T&A was compared with coblation (CAT) and molecular resonance (MR) techniques in a pediatric population. STUDY DESIGN: Prospective analysis of 96 patients (32 for each surgical modality: MPC, MR, or CAT). SETTING: Tertiary care pediatric institution. SUBJECTS AND METHODS: Clinical results, anesthesia and surgery time, bleeding, and cost among these three established techniques were compared. P-values of P < .05 were considered significant for all comparisons. RESULTS: The CAT and MPC had similar operative times (mean 19.2 and 21.1 minutes, respectively, P = NS), whereas the MR group had overall saving of 7.8 minutes in surgery (P < .05). In terms of cost of technology, the cost of the MPC and MR groups was 90.6% and 83.7% less than the CAT group, respectively. CONCLUSIONS: This study demonstrated that MR technique of T&A enabled the surgical team to save a significant amount of time, whereas CAT added substantial costs, compared to MR and standard cautery techniques.
机译:目的:改进的技术声称可在儿童中进行腺扁桃体切除术(T&A)取得更好的临床效果,并且每种技术的发起者年复一年地相互宣扬许多优点。但是,成本仍然是一个变数,并未始终得到彻底解决。在这项研究中,单极电烙术(MPC)的T&A与儿科人群的消融(CAT)和分子共振(MR)技术进行了比较。研究设计:前瞻性分析96例患者(每种手术方式32例:MPC,MR或CAT)。单位:三级儿科机构。研究对象和方法:比较了这三种已建立的技术的临床结果,麻醉和手术时间,出血和费用。对于所有比较,P <.05的P值都被认为是有意义的。结果:CAT和MPC的手术时间相近(分别为19.2和21.1分钟,P = NS),而MR组的手术总时间为7.8分钟(P <.05)。就技术成本而言,MPC和MR组的成本分别比CAT组低90.6%和83.7%。结论:这项研究表明,与MR和标准烧灼技术相比,T&A的MR技术使手术团队节省了大量时间,而CAT则增加了可观的成本。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号