It is mainly for security level problems of important protection items of modern thermal power plant in this article, the main protection including boiler protection and turbine protection and so on, make the standard of SIL used in the control system of thermal power plant, using SIL3 safety level to improve the safety level of the thermal power plant main protection, to ensure safe and stable operation of the whole thermal power plant, at the same time use Laos HONGSA power plant 626MW sub-critical unit as an example, explain further the application of SIL3 used in DCS system and control analysis, through actual parameters of the running unit prove the safety and reliability of the method.
机译:本文主要针对现代火力发电厂重要保护项目的安全等级问题,主要保护措施包括锅炉保护和汽轮机保护等,采用SIL3标准制定了火电厂控制系统中使用的SIL标准。安全等级,提高火电厂主要保护的安全等级,确保整个火电厂安全稳定运行,同时以老挝HONGSA电厂626MW亚临界机组为例,进一步说明应用SIL3在DCS系统中的应用和控制分析,通过运行单元的实际参数证明了该方法的安全性和可靠性。