首页> 外文期刊>Dental Research Journal >The effect of low?level laser 810 nm and light?emitting diode photobiomodulation (626 nm) on the stability of the implant and inflammatory markers interleukin?1 beta and prostaglandin E2, around implants
【24h】

The effect of low?level laser 810 nm and light?emitting diode photobiomodulation (626 nm) on the stability of the implant and inflammatory markers interleukin?1 beta and prostaglandin E2, around implants

机译:低水平激光810 nm和发光二极管的光生物调制(626 nm)对植入物稳定性和炎症标记物白细胞介素1β和前列腺素E2稳定性的影响,在植入物周围

获取原文
           

摘要

Background: One of the most common problems in edentulous patients is the low stability of lower dentures. The most effective method to overcome this problem is implant?supported overdentures. After placing an implant, for the process of osseointegration to be complete and successful, it is better that patients do not use their denture for few months. This may be nonconvenient for patient because they are unable to speak and eat properly. The aim of this study was to evaluate the effect of low level laser (LLL) and light?emitting diode (LED) photobiomodulation on implant stability as well as their effect on interleukin?1 beta (IL?1β) and prostaglandin E2 (PGE2) biomarkers around implant in lower anterior region (over denture). Materials and Methods: In this clinical trial, 36 implants were placed in fully edentulous mandibles (12 people per person ? three implants in areas of midline and canine). Each of the implants was randomly placed in one of three groups of laser, LED, and control. LLL (power of 50 mw and the amount of 20 J/cm2 for each implant) and LED with dose (20 mw/cm2) were irradiated on the day of surgery (zero), 3, 7, 10, and 14 days. The stability of implants was measured on the day of surgery and weeks 3, 4, and 8 after surgery with Periotest. The inflammatory biomarkers of IL?1β and PGE2 were also collected from gingival crevicular fluid around implants in 4 and 8 weeks. The collected data were analyzed by ANOVA statistical tests.pvalue<0.05 considered significant Results: The amounts of Periotest significantly increased 3rd week after surgery in the control group (P < 0.001). However, the laser group and LED group were associated with minimal changes, which indicates lower stability of implant in 3rd week in control group but no changes in stability of test groups (laser and LED). Laser and LED had no effect on the level of IL?1β and PGE2 in 4 and 8 weeks. Conclusion: The use of LLL or LED has a positive effect on the stability of the implants 3 weeks after surgery. Key Words: Dental implants, interleukin, laser, overdentures, prostaglandin E2.
机译:背景:无牙患者最常见的问题之一是下颌假牙的稳定性低。解决此问题的最有效方法是植入物支持的覆盖义齿。放置植入物后,为了使骨整合过程完整且成功,患者最好几个月不使用义齿。对于患者来说这可能不方便,因为他们无法正常说话和进食。这项研究的目的是评估低水平激光(LLL)和发光二极管(LED)光生物调制对植入物稳定性的影响,以及它们对白介素1β(IL1β)和前列腺素E2(PGE2)的影响。下前部种植区(义齿上方)周围的生物标记物。材料和方法:在该临床试验中,将36个植入物放置在完全无牙的下颌骨中(每人12人–在中线和犬齿区域植入3个植入物)。将每种植入物随机放置在激光,LED和对照三组中的一组中。在手术当天(零),3、7、10和14天照射LLL(功率为50 mw,每个植入物的功率为20 J / cm2)和剂量为20 mw / cm2的LED。在手术当天以及手术后第3、4和8周使用Periotest测量植入物的稳定性。在4和8周内,还从植入物周围的龈沟液中收集了ILβ1β和PGE2的炎性生物标志物。收集的数据通过ANOVA统计检验进行分析。p值<0.05被认为是显着的。结果:对照组在手术后第3周Periotest的量显着增加(P <0.001)。但是,激光组和LED组的变化很小,这表明对照组在第3周植入物的稳定性较低,而测试组(激光和LED)的稳定性没有变化。激光和LED在第4和第8周对IL?1β和PGE2的水平没有影响。结论:使用LLL或LED对术后3周的植入物稳定性具有积极作用。关键词:牙种植体,白介素,激光,义齿,前列腺素E2。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号