A new strategy for the detection of rotor electrical asymmetry in wind turbine doubly fed induction generators is presented. In comparison with the previous work, the major novelty of this article is the addition of an adaptive noise cancelation block in the process of detecting the rotor winding fault. This work demonstrates an improvement in the signal-to-noise ratio using robust least mean squares filtering of the wavelet transform method. In the new strategy, robust least mean squares filtering of wavelet transform is used for the first block of fault detection before the fault estimation block. The proposed strategy is verified with the experimental data measured on doubly fed induction generator test rigs and real wind turbine. A comparative study is carried out based on experimental measurements (stator current and power output) under the steady-state and variable-speed operation representative of real wind turbine operations for both healthy and faulty generator conditions.
机译:提出了一种新的风力涡轮机双馈电诱导发电机中转子电不对称的新策略。 与以前的工作相比,本文的主要新颖性是在检测转子绕组故障的过程中添加自适应噪声消除块。 该工作表明使用小波变换方法的鲁棒最小均方块滤波的信噪比提高。 在新的策略中,鲁棒最小均方方的小波变换的滤波用于故障估计块之前的第一故障检测块。 所提出的策略通过在双馈感应发电机试验台和真空风力涡轮机上测量的实验数据进行了验证。 基于实验测量(定子电流和功率输出)下进行比较研究,该稳态和可变速度操作代表健康和故障发生器条件的实际风力涡轮机操作。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号