首页> 外文期刊>Wind Energy >Numerical error estimation of conventional anemometry mounted on offshore floating met-masts
【24h】

Numerical error estimation of conventional anemometry mounted on offshore floating met-masts

机译:安装在海上浮式气象台上的常规风速仪的数值误差估计

获取原文
获取原文并翻译 | 示例
           

摘要

Offshore wind energy is moving towards a future where the main challenge is to cope with the increasing water depth needed to access more and better wind resources. One of the first steps to be undertaken is the development of floating structures to support either wind turbines or measurement devices for the proper characterization of wind energy resources. The use of floating devices for measuring wind speed involves a number of uncertainties not presented by seabed fixed systems. These sources of uncertainty or error are present both in instantaneous wind measurements and averaged (10min or hourly) values because of (i) variability in the measurement height, (ii) the tilt of the anemometer and (iii) the relative velocity between the anemometer and the wind, among others. In this paper, a methodology for assessing the error in the wind measurement characterization because of the movement of a floating meteorological mast is presented. By the numerical simulation of a floating mast, the short- and long-term error in the characterization of the wind at different heights has been evaluated. In general, the error because of the tilt can reach up to 80% of the total error; the error because of the variation of the vertical position of the anemometer reaches values of up to 15% in some cases; moreover, the error associated with the relative velocity between the anemometer and the wind, for averaged values, is significantly less. Finally, it can be concluded that the total error is lower than 0.5% for 10min averaged wind speed of up to 24m/s. Copyright (c) 2016 John Wiley & Sons, Ltd.
机译:海上风能正朝着未来发展,未来的主要挑战是应对获取更多更好风能所需的不断增加的水深。要采取的第一步就是开发浮动结构,以支撑风力涡轮机或测量设备,以正确表征风能资源。使用浮动装置测量风速涉及海底固定系统未提供的许多不确定性。由于(i)测量高度的变化,(ii)风速仪的倾斜度和(iii)风速仪之间的相对速度,在瞬时风速测量和平均(10分钟或每小时)值中都存在这些不确定性或误差源。和风,等等。在本文中,提出了一种用于评估由于浮动气象桅杆的运动而引起的测风特性误差的方法。通过浮动桅杆的数值模拟,已评估了在不同高度的风表征中的短期和长期误差。通常,由于倾斜而引起的误差可高达总误差的80%。在某些情况下,由于风速计垂直位置的变化而导致的误差高达15%。而且,对于平均值,与风速计和风之间的相对速度相关的误差明显较小。最后,可以得出的结论是,对于风速高达24m / s的10分钟,总误差小于0.5%。版权所有(c)2016 John Wiley&Sons,Ltd.

著录项

  • 来源
    《Wind Energy》 |2016年第12期|2287-2300|共14页
  • 作者单位

    Univ Cantabria, Environm Hydraul Inst IH Cantabria, Isabel Torres 15, Santander, Spain;

    Univ Cantabria, Environm Hydraul Inst IH Cantabria, Isabel Torres 15, Santander, Spain;

    Univ Cantabria, Environm Hydraul Inst IH Cantabria, Isabel Torres 15, Santander, Spain;

    Univ Cantabria, Environm Hydraul Inst IH Cantabria, Isabel Torres 15, Santander, Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    floating met-mast; movement; wind measurements error; short and long term;

    机译:漂浮式桅杆;运动;测风误差;短期和长期;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号