This paper details an investigation into the measurement and the prediction of heat-affected zone (HAZ) toughness for construction structural steels. The HAZ toughness was examined using both single-layer and multilayer welded joints, and correlated to the chemical compositions of the steels used. From the series of the tests, the parameter, f_(HAZ), was derived to assess approximately whether a steel plate has adequate HAZ toughness. The condition is shown below. f_(HAZ) ≤ 0.577 for _vE_(273) (single layer) ≥ 30J, _vE_(273)(multilayer) ≥ 70J f_(HAZ) ≤ 0.632 for _vE_(273)(single layer) ≥ 12J, _vE_(273)(multilayer) ≥ 27J f_(HAZ) = C +Mn/8 + 6 (P + S) + 12 N -4 Ti (Note: The content of Ti should be considered as 0 when it is equal to or less than 0.005 mass-%.)
机译:本文详细研究了建筑结构钢的热影响区(HAZ)韧性的测量和预测。使用单层和多层焊接接头检查HAZ韧性,并将其与所用钢的化学成分相关。从一系列测试中,得出参数f_(HAZ)以大致评估钢板是否具有足够的HAZ韧性。条件如下所示。对于_vE_(273)(单层)≥30J,f_(HAZ)≤0.577,_vE_(273)(多层)≥70J对于_vE_(273)(单层)≥12J,_vE_(273)(_ vE_(273)(多层)≥0.632多层)≥27J f_(HAZ)= C + Mn / 8 + 6(P + S)+ 12 N -4 Ti(注:当Ti的含量等于或小于0.005质量时,Ti的含量应视为0 %。)