The current study aims to monitor, detect, and assess post meter water leakage in public areas including schools, graveyards, public toilets, parks, and universities. Twenty-two different public sites were selected within the current study and smart water meters of various sizes were installed in these pilot study sites (PSS). A real time monitoring program was conducted to measure the flow rates at these sites at 15-min time intervals for a period of six months in 2019. The flow occurrence was monitored every two minutes within a user predefined period of inspection, and hence a leak warning message is generated once a continuous flow was detected. Minimum water usage was observed during the minimum night flow (MNF) period from 00:00 to 05:00, therefore close monitoring of the MNF at shorter time intervals allows appropriate leakage detection with proper estimation of leakage volumes. High levels of post meter leakages were observed at all the PSS where the total leakage exceeded 58% of the total flow. On-site investigations and close monitoring revealed that significant water leakage volumes in these PSS are taking place due to poor management practices where deteriorated water connections in toilets and water taps are the main contributing factors to the water leakages in most of these PSS. The results indicated that such huge leakage can be resolved at a low cost. A frequency analysis of the monitored flow rates was found efficient in analyzing the suitability of the installed meter sizes.
机译:目前的研究旨在监测,检测和评估在包括学校,墓地,公共厕所,公园和大学的公共区域的仪表漏水。在目前的研究中选择了二十两种不同的公共场所,并在这些试点研究网站(PSS)中安装了各种尺寸的智能水表。进行了实时监测程序,以在2019年以15分钟的时间间隔测量这些位点的流速。在用户预定义的检查期内每两分钟监测流动发生,从而泄漏一旦检测到连续流程,产生警告消息。在00:00至05:00的最小夜间流动(MNF)期间观察到最小水用法,因此以较短的时间间隔密切地监测MNF,允许适当的泄漏检测,正确估计泄漏量。在所有PSS中观察到高水平的仪表泄漏,总泄漏超过总流量的58%。现场调查和密切监测揭示了这些PSS中的显着漏水卷是由于厕所中的水与水间隙恶化的差,是大多数这些PSS水泄漏的主要因素。结果表明,这种巨大的泄漏可以以低成本解决。在分析安装仪表尺寸的适用性时,发现了监测流量速率的频率分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号