首页> 外文期刊>Water Research >Novel poly (vinyl chloride) matrix membrane electrodes for the determination of phenolic pollutants in waste water
【24h】

Novel poly (vinyl chloride) matrix membrane electrodes for the determination of phenolic pollutants in waste water

机译:新型聚氯乙烯基质膜电极用于测定废水中的酚类污染物

获取原文
获取原文并翻译 | 示例
       

摘要

The construction and electrochemical response characteristics of poly (vinyl chloride) matrix membrane sensors for seven phenolic compounds (phenol, o-cresol, p-cresol, p-chlorophenol, o-nitrophenol, α-naphthol and β-naphthol) are described. The membranes incorporate ion association complexes of these seven phenolic anions with phenanthroline-iron(Ⅱ) as electroactive materials. These sensors show linear response for phenol, o-cresol, p-cresol, p-chlorophenol, o-nitrophenol, α-naphthol, and ?-naphthol over wide concentration ranges, with an average anionic slope 54.3 mV per concentration decade. The suggested sensors exhibit fast response time (1 min), low determination limits (1 x 10~(-5)M), good stability (2-3 weeks), reasonable selectivity to phenolic compounds in the presence of other water pollutants. The average percentage recovery was 99.78 +- 0.088 for individual phenolates and 99.61 +- 0.198 for phenolates in mixtures. The investigated sensors were successfully used for direct potentiometric determination of traces of these phenolic compounds in wastewater samples. Results with mean accuracy of 99.74 +- 0.29%, 99.82 +- 0.36%, 99.65 +- 0.47%, 99.73 +- 0.37%, 99.77 +- 0.30%, 99.86 +- 0.31% and 99.91 +- 0.22% was obtained for the seven sensors, respectively. These results were compared with data obtained using the British pharamacopial method (The British Pharmacopoeia, Her Majesty's Stationary Office, London, 1993) and others (Clarke's Isolation and Identification of Drugs in Pharmaceuticals Body Fluids and Post-mortem Materials, 2nd Edition, The Pharmaceutical Press, London, 1998).
机译:描述了七种酚类化合物(苯酚,邻甲酚,对甲酚,对氯苯酚,邻硝基苯酚,α-萘酚和β-萘酚)的聚(氯乙烯)基质膜传感器的结构和电化学响应特性。该膜结合了这七个酚类阴离子与菲咯啉-铁(Ⅱ)的离子缔合络合物作为电活性物质。这些传感器在宽浓度范围内表现出对苯酚,邻甲酚,对甲酚,对氯苯酚,邻硝基苯酚,α-萘酚和γ-萘酚的线性响应,每个浓度十年平均阴离子斜率为54.3 mV。建议的传感器具有响应时间短(1分钟),测定限低(1 x 10〜(-5)M),稳定性好(2-3周),在存在其他水污染物的情况下对酚类化合物具有合理的选择性的优点。混合物中单个酚盐的平均回收率为99.78±0.088,酚盐的平均回收率为99.61±0.198。研究的传感器已成功用于直接电位滴定法测定废水样品中这些酚类化合物的痕量。获得的结果的平均准确度为99.74±0.29%,99.82±0.36%,99.65±0.47%,99.73±0.37%,99.77±0.30%,99.86±0.31%和99.91±0.22%。七个传感器。将这些结果与使用英国法老法(英国药典,英国女王Her下的固定办事处,伦敦,1993年)和其他数据(克拉克的《体液和验尸材料中药物的分离和鉴定》,第二版,《药物》)进行比较。出版社,伦敦,1998)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号