首页> 外文期刊>Water Research >Determination of organochlorine pesticides and their derivations in water after HS-SPME using polymethylphenylvinylsiloxane-coated fiber by GC-ECD
【24h】

Determination of organochlorine pesticides and their derivations in water after HS-SPME using polymethylphenylvinylsiloxane-coated fiber by GC-ECD

机译:GC-ECD测定聚甲基苯基乙烯基硅氧烷包覆的纤维在HS-SPME之后测定水中的有机氯农药及其衍生物

获取原文
获取原文并翻译 | 示例
       

摘要

A porous sol-gel polymethylphenylvinylsiloxane-coated fiber was applied to optimize the headspace solid-phase microextraction (HS-SPME) conditions for the analysis of 11 organochlorine pesticides (OCPs) and their derivations in water. Their determination was carried out using gas chromatography (GC) with electron capture detector (ECD). The method developed was applied to the analysis of lake water samples. Detection limits varied from 0.835 to 13.0 ng/l and relative standard deviations (RSD ≤ 11.8%) were obtained showing that the precision of the method is reliable. The method also showed good linearity for the tested concentration range with regression coefficients (R~2) ranging between 0.980 and 0.999. Recoveries for all the analytes ranged from 71.5% to 115.5%. The results demonstrate the suitability of the HS-SPME/GC-ECD approach for the analysis of multi-residue OCPs in water.
机译:应用多孔溶胶-凝胶聚甲基苯基乙烯基硅氧烷包覆的纤维优化顶空固相微萃取(HS-SPME)条件,以分析11种有机氯农药(OCP)及其在水中的衍生物。使用气相色谱(GC)和电子捕获检测器(ECD)进行测定。所开发的方法被应用于湖泊水样的分析。检测限从0.835到13.0 ng / l不等,获得的相对标准偏差(RSD≤11.8%)表明该方法的准确性是可靠的。该方法在测试浓度范围内也显示出良好的线性,回归系数(R〜2)在0.980至0.999之间。所有分析物的回收率范围为71.5%至115.5%。结果证明了HS-SPME / GC-ECD方法适用于分析水中的多残留OCP。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号