首页> 外文期刊>Water Research >Activated sludge pilot plant: Comparison between experimental and predicted concentration profiles using three different modelling approaches
【24h】

Activated sludge pilot plant: Comparison between experimental and predicted concentration profiles using three different modelling approaches

机译:活性污泥中试装置:使用三种不同的建模方法比较实验浓度曲线和预测浓度曲线

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents an experimental and numerical study of an activated sludge channel pilot plant. Concentration profiles of oxygen, COD, NO_3 and NH_4 have been measured for several operating conditions. These profiles have been compared to the simulated ones with three different modelling approaches, namely a systemic approach, CFD and compartmental modelling. For these three approaches, the kinetics model was the ASM-1 model (Henze et al., 2001). The three approaches allowed a reasonable simulation of all the concentration profiles except for ammonium for which the simulations results were far from the experimental ones. The analysis of the results showed that the role of the kinetics model is of primary importance for the prediction of activated sludge reactors performance. The fact that existing kinetics parameters in the literature have been determined by parametric optimisation using a systemic model limits the reliability of the prediction of local concentrations and of the local design of activated sludge reactors.
机译:本文介绍了活性污泥通道中试装置的实验和数值研究。对于几种操作条件,已经测量了氧气,COD,NO_3和NH_4的浓度曲线。这些配置文件已通过三种不同的建模方法与模拟的进行了比较,即系统方法,CFD和隔室建模。对于这三种方法,动力学模型是ASM-1模型(Henze等,2001)。这三种方法允许对所有浓度曲线进行合理的模拟,但铵的模拟结果与实验结果相去甚远。结果分析表明,动力学模型的作用对于预测活性污泥反应堆的性能至关重要。文献中现有的动力学参数已通过使用系统模型进行参数优化确定,这一事实限制了预测局部浓度和活性污泥反应器局部设计的可靠性。

著录项

  • 来源
    《Water Research》 |2011年第10期|p.3085-3097|共13页
  • 作者单位

    Laboratoire Reaction et Genie des Precedes, UPR 3349 CNRS, Nancy-Uniuersite, ENSIC, 1 rue Granduille B.P 20451 F-54001 Nancy, France;

    Laboratoire Reaction et Genie des Precedes, UPR 3349 CNRS, Nancy-Uniuersite, ENSIC, 1 rue Granduille B.P 20451 F-54001 Nancy, France;

    Laboratoire Reaction et Genie des Precedes, UPR 3349 CNRS, Nancy-Uniuersite, ENSIC, 1 rue Granduille B.P 20451 F-54001 Nancy, France;

    Laboratoire Reaction et Genie des Precedes, UPR 3349 CNRS, Nancy-Uniuersite, ENSIC, 1 rue Granduille B.P 20451 F-54001 Nancy, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    wastewater treatment plant; experiments; modelling; pollution removal; activated sludge; cfd; compartmental model; systemic model;

    机译:污水处理厂;实验;建模;污染物去除;活性污泥;cfd;区室模型;系统模型;