...
首页> 外文期刊>Water Research >Subcellular mechanism of Escherichia coli inactivation during electrochemical disinfection with boron-doped diamond anode: A comparative study of three electrolytes
【24h】

Subcellular mechanism of Escherichia coli inactivation during electrochemical disinfection with boron-doped diamond anode: A comparative study of three electrolytes

机译:掺硼金刚石阳极电化学消毒过程中大肠杆菌失活的亚细胞机理:三种电解质的比较研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Although the identification of effective oxidant species has been extensively studied, yet the subcellular mechanism of bacterial inactivation has never been clearly elucidated in electrochemical disinfection processes. In this study, subcellular mechanism of Escherichia coli inactivation during electrochemical disinfection was revealed in terms of comprehensive factors such as cell morphology, total organic components, K+ leakage, membrane permeability, lipid peroxidation, membrane potential, membrane proteins, intracellular enzyme, cellular ATP level and DNA. The electrolysis was conducted with boron-doped diamond anode in three electrolytes including chloride, sulfate and phosphate. Results demonstrated that cell inactivation was mainly attributed to damage to the intracellular enzymatic systems in chloride solution. In sulfate solution, certain essential membrane proteins like the K+ ion transport systems were eliminated. Thus, the pronounced K+ leakage from cytosol resulted in gradual collapse of the membrane potential, which would hinder the subcellular localization of cell division-related proteins as well as ATP synthesis and thereby lead to the bacterial inactivation. Remarkable lipid peroxidation was observed, while the intracellular damage was negligible. In phosphate solution, the cells sequentially underwent overall destruction as a whole cell with no captured intermediate state, during which the organic components of the cells were mostly subjected to mineralization. This study provided a thorough insight into the bacterial inactivation mechanism on the subcellular level (C) 2015 Elsevier Ltd. All rights reserved.
机译:尽管对有效氧化剂种类的鉴定已进行了广泛的研究,但是在电化学消毒过程中,细菌灭活的亚细胞机制从未明确阐明。本研究从细胞形态,总有机成分,K +泄漏,膜通透性,脂质过氧化,膜电位,膜蛋白,细胞内酶,细胞ATP水平等综合因素揭示了电化学消毒过程中大肠杆菌失活的亚细胞机制。和DNA。用硼掺杂的金刚石阳极在包括氯化物,硫酸盐和磷酸盐的三种电解质中进行电解。结果表明,细胞失活主要归因于氯化物溶液对细胞内酶系统的破坏。在硫酸盐溶液中,某些必不可少的膜蛋白(如K +离子转运系统)被消除了。因此,从细胞质中明显的K +泄漏导致膜电位逐渐崩溃,这将阻碍细胞分裂相关蛋白的亚细胞定位以及ATP合成,从而导致细菌失活。观察到明显的脂质过氧化作用,而细胞内的损伤可以忽略不计。在磷酸盐溶液中,细胞作为一个整体细胞依次经历了整体破坏,没有捕获的中间状态,在此期间,细胞的有机成分大部分经历了矿化作用。这项研究提供了对亚细胞水平(C)2015 Elsevier Ltd.细菌灭活机制的彻底了解。保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号