Coagulation and ozonation have been widely used as pretreatments for ultrafiltration (UF) membrane in drinking water treatment. While beneficial, coagulation or ozonation alone is unable to both efficiently control membrane fouling and product water quality in many cases. Thus, in this study an emerging alternative of ferrous iron/peroxymonosulfate (Fe(II)/PMS), which can act as both an oxidant and a coagulant was employed prior to UF for treatment of natural surface water, and compared with conventional coagulation and ozonation. The results showed that the Fe(II)/PMS-UF system exhibited the best performance for dissolved organic carbon removal, likely due to the dual functions of coagulation and oxidation in the single process. The fluorescent and UV-absorbing organic components were more susceptible to ozonation than Fe(II)/PMS treatment. Fe(II)/PMS and ozonation pretreatments significantly increased the removal efficiency of atrazine, p-chloronitrobenzene and sulfamethazine by 12-76% and 50-94%, respectively, whereas coagulation exerted a minor influence. The Fe(II)/PMS pretreatment also showed the best performance for the reduction of both reversible and irreversible membrane fouling, and the performance was hardly affected by membrane pore size and surface hydrophobicity. In addition, the characterization of hydraulic irreversible organic foulants confirmed its effectiveness. These results demonstrate the potential advantages of applying Fe(II)/PMS as a pretreatment for UF to simultaneously control membrane fouling and improve the permeate quality. (C) 2017 Elsevier Ltd. All rights reserved.
机译:混凝和臭氧化已被广泛用作饮用水处理中超滤(UF)膜的预处理。尽管有益,但在许多情况下,仅凝结或臭氧化既不能有效控制膜结垢又不能控制产品水质。因此,在这项研究中,UF之前采用了新兴的铁/过一硫酸亚铁(Fe(II)/ PMS)替代品,该替代品既可以用作氧化剂也可以用作混凝剂,用于处理天然地表水,并与常规混凝和臭氧化。结果表明,Fe(II)/ PMS-UF系统表现出最佳的溶解性有机碳去除性能,这可能是由于在单个过程中凝聚和氧化的双重作用。与Fe(II)/ PMS处理相比,荧光和吸收UV的有机组分更易于臭氧化。 Fe(II)/ PMS和臭氧化预处理分别显着提高了阿特拉津,对氯硝基苯和磺胺二甲基嘧啶的去除效率,分别提高了12-76%和50-94%,而混凝作用影响较小。 Fe(II)/ PMS预处理在减少可逆和不可逆膜结垢方面也显示出最佳性能,并且该性能几乎不受膜孔径和表面疏水性的影响。另外,水硬性不可逆有机污垢的表征证实了其有效性。这些结果证明了将Fe(II)/ PMS作为超滤的预处理同时控制膜污染和提高渗透质量的潜在优势。 (C)2017 Elsevier Ltd.保留所有权利。

著录项

  • 来源
    《Water Research》 |2017年第1期|298-307|共10页
  • 作者单位

    Harbin Inst Technol, SKLUWRE, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China;

    Harbin Inst Technol, SKLUWRE, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China;

    Harbin Inst Technol, SKLUWRE, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China;

    Harbin Inst Technol, SKLUWRE, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China;

    Harbin Inst Technol, SKLUWRE, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China;

    Harbin Inst Technol, SKLUWRE, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China;

    Harbin Inst Technol, SKLUWRE, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China;

    Shandong Jianzhu Univ, Sch Municipal & Environm Engn, 1000 Fengming Rd, Jinan 250101, Shandong, Peoples R China;

    Harbin Inst Technol, SKLUWRE, 73 Huanghe Rd, Harbin 150090, Heilongjiang, Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Ferrous iron/peroxymonosulfate (Fe(II)/PMS); Coagulation; Ozonation; Ultrafiltration (UF) membrane; Membrane fouling;

    机译:铁/过一硫酸亚铁(Fe(II)/ PMS);混凝;臭氧化;超滤(UF)膜;膜污染;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号