A novel pyrolusite fluidized bed (PFB) contactor, which we recently developed for dissolved manganese (Mn(II)) removal through surface adsorption and subsequent oxidation by free chlorine, was modeled in this study. The hydrodynamic behavior of the filter media and water in the fluidized bed was described by the axial dispersion model. The model incorporated the effects of axial mixing in the liquid and solid phases, mass transfer resistance in a laminar fluid boundary layer surrounding a media grain, and a second order oxidation rate expression. The experimental data from lab-scale and field pilot-scale contactors was adopted for the model development and its validation. For the former, the data was employed to estimate the oxidation rate constant, the mass transfer coefficient, and the axial solid phase dispersion coefficient for the model. The model simulations matched the experimental data with less than 20% error across a wide range of Mn(II) and free chlorine concentrations and hydraulic loading rates that might be encountered in a drinking water treatment plant. The sensitivity analysis showed that the time to breakthrough is most sensitive to the adsorption isotherm constants and the oxidation rate constant. These observations indicate that the alluded parameters mainly control the performance of the PFB contactor as well as the process stability. Finally, a sample application of the model to acquire operational inputs was illustrated by analyzing the effect of free chlorine concentration on Mn(II) removal performance and breakthrough time within a PFB contactor.
机译:在本研究中,我们对新型的软锰矿流化床(PFB)接触器进行了建模,该接触器是我们最近开发的,用于通过表面吸附去除可溶性锰(Mn(II)),然后通过游离氯氧化。用轴向弥散模型描述了流化床中滤料和水的水动力行为。该模型结合了液相和固相中轴向混合,围绕介质颗粒的层状流体边界层中的传质阻力以及二阶氧化速率表达式的影响。来自实验室规模和现场中试规模接触器的实验数据被用于模型开发和验证。对于前者,该数据用于估计模型的氧化速率常数,传质系数和轴向固相分散系数。模型仿真使实验数据与锰(II)的宽范围误差均小于20%,并且饮用水处理厂可能遇到的游离氯浓度和水力负荷率高。敏感性分析表明,突破时间对吸附等温线常数和氧化速率常数最为敏感。这些观察结果表明,所暗示的参数主要控制PFB接触器的性能以及过程稳定性。最后,通过分析自由氯浓度对PFB接触器中Mn(II)去除性能和穿透时间的影响,说明了该模型用于获取操作输入的示例应用。

著录项

  • 来源
    《Water Research》 |2019年第1期|125-135|共11页
  • 作者单位

    Polytech Montreal, Dept Civil Geol & Min Engn, NSERC Ind Chair Drinking Water, Environm, CP 6079,Succursale Ctr Ville, Montreal, PQ H3C 3A7, Canada;

    Nat Resources Canada, CanmetENERGY, 1 Haanel Dr, Ottawa, ON K1A 1M1, Canada;

    Polytech Montreal, Dept Civil Geol & Min Engn, NSERC Ind Chair Drinking Water, Environm, CP 6079,Succursale Ctr Ville, Montreal, PQ H3C 3A7, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Drinking water; Manganese removal; Pyrolusite fluidized bed contactor; Modeling; Breakthrough;