Optimizing low-level nitrogen removal

机译:优化低水平脱氮

获取原文
获取原文并翻译 | 示例
       

摘要

Problematic nitrogen removal at the Bethune Point Wastewater Treatment Facility in Daytona Beach, Fla., eventually led to pilot-testing of three nonflammable supplemental carbon sources. On-line nitrate analyzers, coupled with a programmable logic controller (PLC), provided a robust process control system. The selected supplemental external carbon source best suited to the five-stage Bardenpho process, combined with the analyzers and PLC, has provided the facility with a more reliable alternative for meeting nitrogen permit limits.
机译:佛罗里达州代托纳比奇的Bethune Point废水处理厂难以解决的脱氮问题,最终导致对三种不可燃的补充碳源进行了中试。在线硝酸盐分析仪与可编程逻辑控制器(PLC)相结合,提供了一个强大的过程控制系统。所选的最适合五阶段Bardenpho工艺的补充外部碳源,与分析仪和PLC相结合,为该设施提供了一种更可靠的替代方案,以满足氮许可的限制。