首页> 外文期刊>Waste Management >Hydrogen sulfide flux measurements from construction and demolition debris (C&D) landfills
【24h】

Hydrogen sulfide flux measurements from construction and demolition debris (C&D) landfills

机译:施工和拆除垃圾(C&D)垃圾填埋场中的硫化氢通量测量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Hydrogen sulfide (H_2S) has been identified as a principal odorous component of gaseous emissions from construction and demolition debris (C&D) landfills. Although several studies have reported the ambient concentrations of H_2S near C&D landfills, few studies have quantified emission rates of H_2S. One of the most widely used techniques for measuring surface gas emission rates from landfills is the flux chamber method. Flux measurements using the flux chamber were performed at five different C&D landfills from April to August, 2003. The flux rates of H2S measured in this research were between 0.192 and 1.76 mg/(m~2-d).
机译:硫化氢(H_2S)已被确定为建筑和拆除垃圾(C&D)垃圾填埋场产生的气体排放的主要臭味成分。尽管有几项研究报告了C&D垃圾填埋场附近H_2S的环境浓度,但很少有研究量化H_2S的排放速率。通量室法是测量垃圾填埋场表面气体排放速率最广泛使用的技术之一。从2003年4月至2003年8月,在五个不同的C&D垃圾填埋场使用通量室进行通量测量。本研究中测量的H2S通量率为0.192至1.76 mg /(m〜2-d)。