首页> 外文期刊>Tunnelling and underground space technology >Effects of fire-blockage distance on pool fire burning behavior and thermal temperature profiles in a naturally ventilated tunnel
【24h】

Effects of fire-blockage distance on pool fire burning behavior and thermal temperature profiles in a naturally ventilated tunnel

机译:防火距离对自然通风隧道池火灾燃烧行为和热温曲线的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Previously, investigation of blockage effect on the fire burning behavior and thermal characteristic was mostly conducted in longitudinally ventilated tunnels. This paper predominately concentrated on the pool fire burned in a naturally ventilated tunnel considering blockage effect caused by the vehicle and wall restriction due to the closed portal. A total number of 45 reduced scale experiments were carried out in a 1/15 model tunnel where pool fires loaded in five fuel pans were burned with and without blockage. Two blockages were individually placed upstream of the fire at five locations to investigate the impact of fire-blockage distance L-fb and blockage ratio. Results declared the key findings as: 1) blockage nearby the pool fire results in asymmetric entrainment of fire plume, due to which flame of the pool fire swings severely during the combustion; 2) burning rate of the pool fire significantly increases when the fire-blockage distance L-fb decreases, attributed to the enhanced heat feedback from the blockage. For the two blockages adopted in the present work, burning rate increases as blockage ratio increases; 3) ceiling temperature decreases as the fire-blockage distance L-fb increases. An empirical model was established to correlate ceiling temperature decay upstream of the fire with fire-blockage distance L-fb. Comparison between the predicted model and experimental values indicates good agreement.
机译:此前,对火灾燃烧行为和热特性的阻塞效应的调查主要是在纵向通风隧道中进行的。本文主要集中在池火上,在自然通风的隧道中燃烧,考虑到由封闭式门户的车辆和墙壁限制引起的阻塞效果。在1/15模型隧道中进行了45个减少的规模实验,其中池燃料装入五个燃料平底锅中被烧毁,没有堵塞。在五个位置单独放置两个堵塞,以研究防火距离L-FB和堵塞比的影响。结果宣布为以下关键结果:1)池火灾堵塞的堵塞导致消防羽流不对称夹带,由于池火灾在燃烧过程中严重摇摆的火焰; 2)当防火距离L-FB减小时,池火灾的燃烧速率显着增加,归因于堵塞的增强热反馈。对于本作中采用的两个堵塞,燃烧率随着阻塞比的增加而增加; 3)由于火阻塞距离L-FB增加,天花板温度降低。建立了经验模型,以将火灾距离L-FB与火灾上游的天花板温度衰减相关。预测模型和实验值之间的比较表明良好的一致性。

著录项

  • 来源
    《Tunnelling and underground space technology》 |2021年第11期|104131.1-104131.14|共14页
  • 作者单位

    Chongqing Univ Sch Civil Engn Chongqing 400045 Peoples R China;

    Chongqing Univ Sch Civil Engn Chongqing 400045 Peoples R China;

    Chongqing Univ Coll Environm & Ecol Chongqing 400045 Peoples R China;

    Chongqing Univ Sch Civil Engn Chongqing 400045 Peoples R China;

    Chongqing Univ Sch Civil Engn Chongqing 400045 Peoples R China|Chongqing Univ Minist Educ Key Lab New Technol Construct Cities Mt Area Chongqing 400045 Peoples R China|Joint Int Res Lab Green Bldg & Built Environm Chongqing 400045 Peoples R China;

    Chongqing Univ Sch Civil Engn Chongqing 400045 Peoples R China|Chongqing Univ Minist Educ Key Lab New Technol Construct Cities Mt Area Chongqing 400045 Peoples R China|Joint Int Res Lab Green Bldg & Built Environm Chongqing 400045 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Burning rate; Ceiling temperature; Blockage effect; Pool fire; Closed portal; Tunnel fire;

    机译:燃烧率;天花板温度;堵塞效果;池火;封闭式门户;隧道火灾;

相似文献