...
首页> 外文期刊>Transactions of the ASABE >Odor Concentrations Downwind of Idaho Dairies and Heifer Facilities
【24h】

Odor Concentrations Downwind of Idaho Dairies and Heifer Facilities

机译:爱达荷州奶牛场和小母牛设施的气味浓度偏低

获取原文
获取原文并翻译 | 示例

摘要

Odor and gas concentrations were sampled on 38 dairies and 15 heifer and calf raising facilities in southern Idaho. Odor detection threshold was measured using a Nasal Ranger field olfactometer, and odor intensity was measured using n-butanol. Gas concentrations for total reduced sulfur (hydrogen sulfide) were measured at each farm's most probable odor source, 50 m downwind, and 200 m downwind using a Jerome meter, and ammonia was measured using Dräger diffusion tubes. The type and management of manure handling systems were found to have the greatest impact on odor concentration versus the number of animals on the facility. There were observations of individual facilities within each subject group that emitted odors much less and up to twice the group averages. Flushed freestall and scraped freestall systems were shown to have the greatest measured odor concentrations, while open-lot facilities had lower measured levels. Seasonal variations on each type of dairy studied were found to have a significant impact on odor and gas concentrations at the source. Odor concentrations from heifer facilities were found to be similar to those of open-lot dairies. Porous geotextile covers used on secondary manure separation basins were found to be effective in reducing odor concentrations by half. Odors that were in excess of 15 dilutions to threshold, using the Nasal Ranger, were found to be objectionable when odor panelists were located at a rural residence during 50% of the odor measurements. Panelists observing the same level of odor would have found it objectionable nearly 80% of the time if the odor were detected during a party or event at a rural residence
机译:在爱达荷州南部的38个奶牛场和15个小母牛和犊牛饲养设施中采样了气味和气体浓度。使用Nasal Ranger现场嗅觉仪测量气味检测阈值,并使用正丁醇测量气味强度。使用Jerome流量计在每个农场最可能的气味源,顺风50 m和顺风200 m处测量总还原硫(硫化氢)的气体浓度,并使用Dräger扩散管测量氨。发现粪便处理系统的类型和管理方式对臭味浓度的影响最大,而设施上的动物数量却很少。在每个受试者组中观察到的单个设施散发出的气味少得多,最高达到组平均值的两倍。结果表明,冲free的和st刮的系统的气味浓度最高,而露天设施的measured测水平较低。研究发现,每种类型的乳制品的季节变化都会对源头的气味和气体浓度产生重大影响。发现小母牛设施的气味浓度与露天奶牛场相似。人们发现,用于次级粪便分离池的多孔土工织物覆盖物可有效地将气味浓度降低一半。当在50%的气味测量过程中,气味专家小组成员位于农村住宅时,使用Nasal Ranger超过15倍稀释到阈值的气味被认为是令人反感的。观察到相同气味的小组成员将发现,如果在农村居民的聚会或活动中检测到气味,将近80%的时间令人反感

著录项

  • 来源
    《Transactions of the ASABE 》 |2007年第1期| p.255-263| 共9页
  • 作者单位

    Ronald E. Sheffield, ASABE Member Engineer, Assistant Professor, Department of Biological and Agricultural Engineering, Twin Falls Research and Extension Center, University of Idaho, Twin Falls, Idaho;

    Mireille Chahine, Assistant Professor, Department of Animal and Veterinary Science, Twin Falls Research and Extension Center, University of Idaho, Twin Falls, Idaho;

    Bobby Dye, Research Assistant, Department of Health Science, Boise State University, Boise, Idaho;

    and Matthew B. Thompson, Owner and Professional Engineer, Ag Technical Engineering and Environmental Associates, Twin Falls, Idaho. Corresponding author: Dr. Ronald E. Sheffield, Twin Falls Research and Extension Center, University of Idaho, P.O. Box 1827, Twin Falls, ID 83303;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Dairy; Heifer facility; Nasal Ranger; Odor;

    机译:乳制品小母牛设施;鼻游侠;气味;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号