首页> 外文期刊>TRANSACTIONS OF NANJING UNIVERSITY OF AERONAUTICS & ASTRONAUTICS >RELIABLE HYSTERESIS CURRENT CONTROLLED DUAL BUCK HALF BRIDGE INVERTER
【24h】

RELIABLE HYSTERESIS CURRENT CONTROLLED DUAL BUCK HALF BRIDGE INVERTER

机译:可靠的迟滞电流控制双降压半桥逆变器

获取原文
获取原文并翻译 | 示例
           

摘要

A highly efficient and reliable topology ― dual buck half bridge inverter (DBI) is introduced. The existence of discontinuous conduction mode (DCM ) operation state requires the bias of inductor current for DBI implemented with linear controllers like ramp comparison SPWM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis current controlled dual buck half bridge inverter (HCDBI) are proposed. The bias current required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational scheme and control strategy are presented. Power losses of the conventional half bridge inverter (CHBI) and HCDBI are compared with mathematical computation, and experimental verification is also executed. Both calculational and experimental results verify that HCDBI has a superior switching performance over CHBI. Its excellent high frequency operational capacity provides another access to realize high frequency operation of inverters.
机译:引入了一种高效且可靠的拓扑-双降压半桥逆变器(DBI)。不连续传导模式(DCM)工作状态的存在要求使用线性控制器(如斜坡比较SPWM(RCSPWM)控制器)实现的DBI的电感器电流偏置。提出了一种新的DBI工作方案和一个磁滞电流控制双降压半桥逆变器(HCDBI)。消除了RCSPWM DBI所需的偏置电流,并大大降低了传导损耗。 HCDBI凭借其出色的命令跟踪功能,极大地提高了DCM区域的调制性能。介绍了运行方案和控制策略。将常规半桥逆变器(CHBI)和HCDBI的功率损耗与数学计算进行比较,并进行实验验证。计算结果和实验结果均证明HCDBI具有优于CHBI的切换性能。其出色的高频运行能力为实现逆变器的高频运行提供了另一种途径。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号