Critical heat flux during pool boiling on a wire or plate vertical heater has been measured employing water and refrigerant R113. The experiment was carried out using wires 0.5 to 2 mm in diameter and plates 5,7, and 30mm in width. The height of the heater ranges from 20 to 3000 mm and the pressurer were 1 and 2 bar for water and 1,2,3, and 4 bar for R113. The results show that in the cases of both wires and the plate 5 and 7 mm in width, a large coalesced bubble entirely surrounds the vertical heater and rises surrounding it, while for the plate with w=30 mm, a large bubble cannot surround and rises along its surface.
机译:已经使用水和制冷剂R113测量了在金属丝或平板垂直加热器上池沸腾期间的临界热通量。使用直径为0.5到2毫米的金属丝,宽度为5,7和30毫米的金属板进行实验。加热器的高度在20到3000 mm之间,加压器的进水压力为1和2 bar,R113的压力为1,2,3和4 bar。结果表明,在电线和宽度分别为5和7 mm的板的情况下,大的聚结气泡完全围绕垂直加热器并围绕其上升,而对于w = 30 mm的板,较大的气泡不能围绕并围绕沿其表面上升。