首页> 外文期刊>Thin-Walled Structures >Experimental investigation of built-up cold-formed steel section battened columns
【24h】

Experimental investigation of built-up cold-formed steel section battened columns

机译:组合式冷弯型钢支撑条的试验研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper presents an experimental investigation on behaviour and design of built-up cold-formed steel section battened columns. The built-up columns were pin-ended and consisted of two cold-formed steel channels placed back-to-back at varied spacing of intersection. The two channels were connected using batten plates, with varying longitudinal spacing. The cold-formed steel channel sections were manufactured by brake-pressing flat strips having a plate thickness of 2 mm. The built-up cold-formed steel section battened columns had different slenderness and geometries but had the same nominal length of 2200 mm. The column strengths, load-axial shortening, load-lateral displacement and loadaxial strain relationships were measured in the tests. In addition, the failure modes and deformed shapes at failure were observed in the tests and reported in this paper. Overall, the built-up column tests provided valuable experimental data regarding the column behaviour that compensated the lack of information on this form of construction as well as used to develop nonlinear 3-D finite element models. The column strengths measured experimentally were compared against design strengths calculated using the North American Specification, Australian/New Zealand Standard and European Code for coldformed steel columns. Generally, it is shown that the specifications were unconservative for the built-up cold-formed steel section battened columns failing mainly by local buckling, while the specifications were conservative for the built-up columns failing mainly by elastic flexural buckling. (C) 2015 Elsevier Ltd. All rights reserved.
机译:本文提出了对组合式冷弯型钢压杆的性能和设计的实验研究。组合柱是销钉固定的,由两个冷弯的钢制通道组成,它们以不同的相交间距背对背放置。两个通道使用板条板连接,纵向间隔不同。通过对板厚为2mm的扁平条进行制动加压来制造冷弯型钢通道段。组合式冷弯型钢压条柱具有不同的细长度和几何形状,但具有相同的标称长度2200 mm。在测试中测量了圆柱强度,轴向载荷的缩短,轴向位移和轴向应变的关系。此外,在测试中观察到了破坏模式和破坏时的变形形状,并在本文中进行了报道。总体而言,内置的柱测试提供了有关柱行为的宝贵实验数据,这些数据弥补了这种构造形式的信息不足,并用于开发非线性3-D有限元模型。将实验测量的柱强度与使用北美规范,澳大利亚/新西兰标准和欧洲规范的冷弯钢柱计算的设计强度进行比较。通常,已表明,对于主要通过局部屈曲破坏的组合式冷弯型钢截面受压柱,该规格不保守,而对于主要由于弹性挠曲屈曲破坏的组合式柱体的规格较保守。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号