首页> 外文期刊>Thin-Walled Structures >Experimental investigation and a novel direct strength method for cold-formed built-up I-section columns
【24h】

Experimental investigation and a novel direct strength method for cold-formed built-up I-section columns

机译:冷成型组合工字型柱的试验研究和新型直接强度方法

获取原文
获取原文并翻译 | 示例

摘要

This paper aims at investigating the structural response and predicting the ultimate strength of the cold-formed built-up I-section columns affected by local, distortional, global and in particular by the local-distortional (LD) interactive and local-distortional-global (LDG) interactive buckling modes. For this purpose, a total of 18 single C-section columns and 18 built-up I-section columns were tested under uniaxial compression load, respectively. The cross-sectional dimension, the thickness and the length of the tested members were varied in the test so as to cover a wide range of local, distortional and overall slenderness. It was shown in the test that noticeable LD interaction was observed for a built-up column with short length as well as LDG interaction for a built-up column with intermediate length. Due to the clear evidence obtained in the test that LD and LDG interactions cause substantial ultimate strength erosion in cold-formed built-up I-section column, a novel direct strength based method was proposed in this paper to quantify such an erosion effect. The validity of the proposed method was then verified by comparing the results obtained from the proposed method with the test results in this paper as well as several other test results in the literature. The comparison results proved that the proposed method can be used successfully in estimating the ultimate strength of cold-formed built-up I-section column affected by pure buckling mode as well as interactive buckling mode.
机译:本文旨在研究受局部,变形,整体,尤其是局部-局部(LD)相互作用和局部-局部-整体影响的冷弯组合式I型截面柱的结构响应并预测其极限强度(LDG)交互式屈曲模式。为此目的,分别在单轴压缩载荷下分别测试了总共18个单C形截面柱和18个组合式I形柱。在测试中,改变被测构件的横截面尺寸,厚度和长度,以覆盖大范围的局部,变形和整体细长。在测试中显示,对于长度较短的组合柱,观察到了明显的LD相互作用,而对于中等长度的组合柱,则观察到了LDG的相互作用。由于在试验中获得了明确的证据,即LD和LDG的相互作用会在冷弯成型的I型截面柱中引起相当大的极限强度腐蚀,因此本文提出了一种基于直接强度的新颖方法来量化这种腐蚀效果。然后,通过比较从该方法获得的结果与本文中的测试结果以及文献中的其他几个测试结果,验证了该方法的有效性。比较结果表明,所提出的方法可以成功地估算受纯屈曲模态和相互作用屈曲模态影响的冷成型组合工字型柱的极限强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号