A differential AC chip calorimeter based on commercially available sensors is described. Due to the differential setup pJK~(-1) sensitivity is achieved. Heat capacity can be measured for sample masses below one nanogram. This corresponds to heat capacities below one nJK~(-1) even above room temperature as needed for the study of the glass transition in nanometer thin polymeric films. The calorimeter allows for the frequency dependent measurement of complex heat capacity in the broad frequency range from 1 Hz to 1 kHz for sample masses of some nanograms.
机译:描述了一种基于市售传感器的差动AC芯片量热仪。由于采用了差分设置,因此可以实现pJK〜(-1)灵敏度。可以测量低于1纳克的样品质量的热容量。这相当于研究纳米薄聚合物薄膜的玻璃化转变所需的甚至低于室温的低于1 nJK〜(-1)的热容量。量热仪可对几纳克的样品质量在1 Hz至1 kHz的宽频率范围内进行频率相关的复热容量测量。