This paper presents a strategy for achieving metrological traceability using vector network analyzers (VNAs) at submillimeter-wave frequencies (300-3000 GHz). The strategy includes the use of traceable calibration techniques designed for operation at these frequencies. Slight, but significant, physical differences between the waveguide line standards, used during calibration, are accommodated by applying a weighting technique to combine results using different calibration lines. Measurement uncertainty is assessed by analyzing replicate measurement data, to take account of the different waveguide interface interactions that occur when the line standards are connected to the VNA. The strategy is illustrated using measurements made in the WM-250 (750-1100 GHz) waveguide band.
机译:本文提出了一种使用矢量网络分析仪(VNA)在亚毫米波频率(300-3000 GHz)上实现计量可追溯性的策略。该策略包括使用为在这些频率下运行而设计的可追溯校准技术。通过应用加权技术来合并使用不同校准线的结果,可以适应校准期间使用的波导线标准之间的微小但明显的物理差异。通过分析重复的测量数据来评估测量不确定度,以考虑到将线标准连接到VNA时发生的不同波导界面相互作用。使用在WM-250(750-1100 GHz)波导频带中进行的测量来说明该策略。