Purpose - The purpose of this paper is to discuss the methodobgy and results of using thermography for pre-retrofit (pre-R:T) and post-retrofit (post-RT) surveys undertaken to qualitatively assess retrofitted external wall insulation (EWI) on pre-1919 existing dwellings with solid exterior walls. Design/methodology/approach - This study involved undertaking qualitative thermography surveys before and after installation of EWI at two mid-terrace dwellings in Swansea (UK). One dwelling was part of a whole-street approach and the other was an isolated installation. Findings - The two case studies have provided evidence of potential thermal bridges created as a result of an incomplete covering of EWI. Whilst overall heat loss appears to have been reduced, further evidence is required to establish the extent to which these thermal bridges reduce overall thermal performance. Research limitations/implications - Only two schemes undertaken in Swansea (UK) are represented in this study and are therefore not a reflection of EWI installations generally. Nevertheless, the study suggests more general concerns with the installation of EWI where a continuous covering of insulation cannot be achieved. Further research is required to assess the long-term implications of thermal bridges on the condition of the dwelling and the health of occupants. Originality/value - This paper has introduced and tested a pre-R:T and post-R:T methodology for assessing the thermal performance of deprived dwellings, which have had EWI retrofitted to solid exterior walls. By using the pre-R:T and post-R:T methodology the paper has demonstrated a visual method for illustrating problems in retrofitting EWI and highlighted improvements in thermal performance, which can be used by stakeholders involved in the maintenance and improvement of existing dwellings.
机译:目的-本文的目的是讨论使用热成像技术对改造前(R:T)和改造后(RT)进行热成像的方法学和结果,以定性评估改造后的外墙保温材料(EWI) 1919年之前的现有房屋,外墙坚固。设计/方法/方法-这项研究涉及在英国斯旺西的两座中层住宅安装EWI之前和之后进行定性热成像调查。一所住宅是整条街道的一部分,另一所是隔离的设施。调查结果-这两个案例研究提供了EWI覆盖不完全导致潜在的热桥的证据。尽管总的热量损失似乎有所减少,但还需要进一步的证据来确定这些热桥降低总体热性能的程度。研究的局限性/意义-这项研究仅代表了在英国斯旺西实施的两种方案,因此,这通常并不反映EWI安装的情况。但是,研究表明,在无法连续覆盖绝缘层的情况下,安装EWI会引起更多的普遍关注。需要进一步的研究来评估热桥对居住条件和居住者健康的长期影响。原创性/价值-本文介绍并测试了R:T之前和R:T之后的方法,用于评估将EWI改造为坚固外墙的贫困住宅的热性能。通过使用R:T之前和R:T之后的方法,本文展示了一种直观的方法来说明EWI改造中的问题,并着重指出了热性能方面的改进,参与现有住房维护和改进的利益相关者可以使用该方法。 。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号