首页> 外文期刊>Structural Engineering and Mechanics >Study on axial compressive behavior of quadruple C-channel built-up cold-formed steel columns
【24h】

Study on axial compressive behavior of quadruple C-channel built-up cold-formed steel columns

机译:四重型C渠道建筑冷成型钢柱轴向压缩行为研究

获取原文
获取原文并翻译 | 示例

摘要

In this study, the axial compressive behavior of novel quadruple C-channel built-up cold-formed steel columns with different slenderness ratio was investigated, using the experimental and numerical analysis. The axial compressive capacity and failure modes of the columns were obtained and analyzed. The finite element models considering the geometry, material and contact nonlinearity were developed to simulate and analyze the structural behavior of the columns further. There was a great correlation between the numerical analyses and test results, which indicated that the finite element model was reasonable and accurate. Then influence of, slenderness ratio, flange width-to-thickness ratio and screw spacing on the mechanical behavior of the columns were studied, respectively. The tests and numerical results show that due to small slenderness ratio, the failure modes of the specimens are generally local buckling and distortional buckling. The axial compressive strength and stiffness of the quadruple C-channel built-up cold-formed steel columns decrease with the increase of maximum slenderness ratio. When the screw spacing is ranging from 150mm to 450mm, the axial compressive strength and stiffness of the quadruple C-channel built-up cold-formed steel columns change little. The axial compressive capacity of quadruple C-channel built-up cold-formed steel columns increases with the decrease of flange width-thickness ratio. A modified effective length factor is proposed to quantify the axial compressive capacity of the quadruple C-channel built-up cold-formed steel columns with U-shaped track in the ends.
机译:在这项研究中,使用实验性和数值分析,研究了新型四维C沟道内置冷成型钢柱的新型四维C沟道的轴向压缩行为。获得并分析了柱的轴向压缩容量和故障模式。考虑几何形状,材料和接触非线性的有限元模型是开发出来的,进一步模拟和分析柱的结构行为。数值分析和测试结果之间存在很大的相关性,这表明有限元模型合理且准确。然后,分别研究了对柱的力学行为的影响,细长比,法兰宽度到厚度比和螺杆间距的影响。测试和数值结果表明,由于小细长比例,标本的失效模式通常是局部屈曲和扭曲的屈曲。通过最大细长比率的增加,四重C沟道内置冷成型钢柱的轴向抗压强度和刚度降低。当螺杆间距为150毫米至450mm时,四重C沟道内置冷成型钢柱的轴向抗压强度和刚度变化很少。四元C沟道内置冷成型钢柱的轴向压缩容量随着法兰宽度厚度比的降低而增加。提出了一种改进的有效长度因子,以量化二元C沟道内置冷成型钢柱的轴向压缩容量,其末端具有U形轨道。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号