This paper deals with the numerical model of a bracing-friction damper system and its deployment using the optimal slip load distribution for the seismic retrofitting of a damaged building. The Slotted Bolted Connection (SBC) type friction damper system was tested to investigate its energy dissipation characteristic. Test results coincided with the numerical ones using the conventional model of a bracing-friction damper system. The placement of this device was numerically explored to apply it to the assumed damaged-building and to evaluate its efficiency. It was found by distributing the slip load that minimizes the given performance indicies based on structural response. Numerical results for the damaged building retrofitted with this slip load distribution showed that the seismic design of the bracing-friction damper system under consideration is effective for the structural response reduction.
机译:本文研究了支撑-摩擦阻尼器系统的数值模型,并使用最佳滑移载荷分布进行了部署,以对受损建筑物进行地震改造。对开槽螺栓连接(SBC)型摩擦阻尼器系统进行了测试,以研究其能量耗散特性。测试结果与使用支撑-摩擦阻尼器系统的常规模型的数值结果一致。对该设备的放置进行了数值研究,以将其应用于假定的受损建筑物并评估其效率。通过分布滑动载荷可以发现,该滑动载荷可根据结构响应将给定的性能指标最小化。用这种滑移载荷分布进行改造的受损建筑物的数值结果表明,所考虑的支撑-摩擦阻尼器系统的抗震设计对于降低结构响应是有效的。