首页> 外文期刊>Smart Grid, IEEE Transactions on >Voltage and Frequency Recovery in an Islanded Inverter-Based Microgrid Considering Load Type and Power Factor
【24h】

Voltage and Frequency Recovery in an Islanded Inverter-Based Microgrid Considering Load Type and Power Factor

机译:考虑负载类型和功率因数的基于孤岛式逆变器的微电网中的电压和频率恢复

获取原文
获取原文并翻译 | 示例
           

摘要

This paper introduces simple and complete under voltage-frequency load shedding schemes to determine proper load shedding amounts (LSAs) in an islanded inverter-based microgrids (IBMGs) considering power and power factor (PF) of various load types, such as constant power, constant current, and constant impedance loads. The proposed method employs a fast time-step simulation approach based on the complete state-space model of IBMG in order to obtain the transient and steady state responses of the system. The required power-voltage curves are obtained considering load PF and system topology. Ultimately, LSA is obtained according to the under voltage load shedding (LS) and under frequency LS values. To demonstrate the effectiveness of the proposed simple and complete LS methods, the corresponding performances are analyzed in a test islanded IBMG modeled in MATLAB. The simulation results show that unlike the other compared methods, the proposed LS approach can accurately determine less LSA while maintaining the power system stability.
机译:本文介绍了简单而完整的低电压-频率减载方案,以在考虑各种负载类型(例如恒定功率)的功率和功率因数(PF)的情况下,在基于孤岛的基于逆变器的微电网(IBMG)中确定适当的减载量(LSA)。恒定电流和恒定阻抗负载。为了获得系统的瞬态和稳态响应,该方法采用了基于完整的IBMG状态空间模型的快速时步仿真方法。考虑到负载功率因数和系统拓扑,可获得所需的功率-电压曲线。最终,根据欠压减载(LS)和低频LS值获得LSA。为了证明所提出的简单而完整的LS方法的有效性,在MATLAB中建模的测试孤岛IBMG中分析了相应的性能。仿真结果表明,与其他比较方法相比,本文提出的最小二乘方法能够在保持电力系统稳定的同时,准确地确定较少的最小二乘法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号