首页> 外文期刊>Sensors and materials >Enzymatic Conductometric Biosensorbased On Pvc Membrane Containingrnmethyl Viologenafion~ritrate Reductase Forrndetermination Of Nitrate In Natural Water Samples
【24h】

Enzymatic Conductometric Biosensorbased On Pvc Membrane Containingrnmethyl Viologenafion~ritrate Reductase Forrndetermination Of Nitrate In Natural Water Samples

机译:含甲基紫精/ nafion〜r /硝酸还原酶的pvc膜酶促电导生物传感器测定天然水样中的硝酸盐

获取原文
获取原文并翻译 | 示例
           

摘要

A highly sensitive, fast, and stable conductometric enzyme biosensor for the determination of nitrate in water is described and validated in natural water samples. The nitrate biosensor is based on a methyl viologen mediator mixed with nitrate reductase (NR) from Aspergillus niger and Nafion~R cation-exchange polymer dissolved in a plasticized PVC membrane deposited on the sensitive surface of interdigitated electrodes. The process parameters for the fabrication of the enzyme biosensor and various measuring conditions such as pH buffer concentration and temperature were investigated with regard to their effect on sensitivity, limit of detection, dynamic range and operational and storage stabilities. The sensitivity of the nitrate sensor was approximately 1.48 μSL/mg, the detection limit was 1.2 μg/L, and linear calibration was in the range from 4×10~(-3) to 8 mg/L with an application domain from 4×10~(-3) to 50 mg/L. When stored in 20 mM phosphate buffer (pH 7.5) at 4℃, the sensor showed good stability over 2 months.
机译:一种用于测定水中硝酸盐的高度灵敏,快速且稳定的电导酶生物传感器,已在天然水样品中进行了描述和验证。硝酸盐生物传感器基于甲基紫精介体,与来自黑曲霉的硝酸盐还原酶(NR)和溶解在叉指电极敏感表面上的增塑PVC膜中的Nafion_R阳离子交换聚合物混合。研究了酶生物传感器的制造工艺参数以及各种测量条件(例如pH缓冲液浓度和温度)对灵敏度,检测极限,动态范围以及操作和存储稳定性的影响。硝酸盐传感器的灵敏度约为1.48μSL/ mg,检出限为1.2μg/ L,线性校正范围为4×10〜(-3)至8 mg / L,应用范围为4× 10〜(-3)至50 mg / L。当在4℃下于20 mM磷酸盐缓冲液(pH 7.5)中存储时,传感器在2个月内显示出良好的稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号