The pressure head at a point inside a flowing fluid through a pipeline decreases with the increase of flow rate according to Bernoulli's equation. The measurement of flow rate by measuring this pressure is not generally used since decrease of pressure is very small compared with static pressure at no flow. In this paper, a modified differential inductance-type technique has been developed to measure the flow rate of a fluid by measuring only this change in pressure without using any obstruction in the pipeline. A differential inductance-type pressure transducer using two identical Bourdon tubes as the primary sensing elements, has been designed and developed to measure the small decrease of pressure due to flow of fluid in a horizontal pipeline. The transducer has been used to measure the flow rate of tap water through a pipeline. The basic theoretical equations describing the operation of the transducer have been derived. The transducer has been experimentally tested and the experimental results are reported in this paper. The experimental characteristic is found to follow the theoretical equations with good repeatability.
机译:根据伯努利方程,在流经管道的流体内部的某个点的压头随流量的增加而减小。通常不使用通过测量该压力来测量流量的方法,因为与无流量的静态压力相比,压力的降低非常小。在本文中,已开发出一种改进的差分电感型技术,通过仅测量压力的这种变化而不会在管道中造成任何障碍来测量流体的流量。设计和开发了一种使用两个相同的波登管作为主要传感元件的差分电感型压力传感器,以测量由于水平管道中的流体流动而引起的压力的小幅下降。该传感器已用于测量通过管道的自来水的流量。推导了描述换能器操作的基本理论方程。该换能器已经过实验测试,并在本文中报告了实验结果。发现实验特性遵循具有良好重复性的理论方程式。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号