This paper presents a significantly improved method for measuring the temperature sensitivity of phase modal birefringence of polarization-maintaining optical fibers (PMFs) based on the Sagnac interferometer. In this method, a measurement of the spectral temperature sensitivity of a PMF-based Sagnac interferometer temperature sensor is performed. The measured spectral temperature sensitivity of the sensor is used to determine the polarimetric temperature sensitivity of the PMF, and with the additionally measured phase modal birefringence, to determine its temperature sensitivity of phase modal birefringence based on the derived equations relating these quantities to the spectral temperature sensitivity of the sensor. The temperature sensitivity of group modal birefringence of the fiber was calculated on the basis of its already determined temperature sensitivity of phase modal birefringence. In addition, a new procedure for determining the sign of the group modal birefringence was given, and new procedures for determining the signs of the temperature sensitivities of phase modal birefrigence and group modal birefringence of a PMF were also given. Using the proposed method, the measurements of PMFs were performed: a polarization maintaining photonic crystal fiber (PM-PCF) and a PANDA PMF, in the temperature range 20 °C–70 °C, for the wavelength range 1500–1600 nm. A comparison of the results of these measurements with results obtained by other methods for the same types of fibers is presented.
机译:本文提出了一种基于Sagnac干涉仪的,用于测量保偏光纤(PMF)的相位模态双折射温度灵敏度的显着改进方法。在这种方法中,对基于PMF的Sagnac干涉仪温度传感器的光谱温度灵敏度进行了测量。传感器测得的光谱温度灵敏度用于确定PMF的偏振温度灵敏度,并与附加测得的相位模态双折射一起,基于将这些量与光谱温度相关联的导出方程式,确定其相位模态双折射的温度灵敏度。传感器的灵敏度。基于已经确定的相模态双折射的温度敏感性,来计算光纤的组模态双折射的温度敏感性。另外,给出了确定群模态双折射的符号的新方法,并且给出了确定相模态双折射和PMF的群模态双折射的温度敏感性的符号的新程序。使用提出的方法,进行了PMF的测量:保偏光子晶体光纤(PM-PCF)和PANDA PMF,温度范围为20°C–70°C,波长范围为1500–1600 nm。这些测量的结果与通过其他方法获得的相同类型纤维的结果进行了比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号