NF-κB is a protein complex found in almost all animal cell types that act as a transcription factor. Conventional methods for the study of NF-κB, however, are time-consuming, and most require radioactive labeling. The aim of this study was to develop a rapid method to study NF-κB by use of a direct specific binding DNA-based biosensor based on a quartz crystal microbalance (QCM). A specific DNA probe was designed and modified by the sulfhydryl group on the 5-Terminal to be immobilized on the gold coated surface of 10 MHz piezoelectric quartz crystal to construct the QCM biosensor to detect NF-κB. We made calibration curves after immobilization of probe at an optimal concentration and then evaluated the performance characteristics of the sensor with a series of tests. In addition, we measured clinical samples with both QCM sensor array and ELISA to assess the QCM sensor. Under optimal conditions, the response frequency of piezoelectric biosensor was linearly dependent on NF-kB concentrations in the range of 0.25 ng/μX to 50 ng/μL with relative standard deviation (RSD) of intra-assay and inter-assay less than 10%. The QCM system we designed has the advantages of being rapid, simple operation, label-free, cheap, sensitive and could be a useful supplement to commercial assay methods in the study of NF-κB, such as NF-κB binding, NF-κB quantitation, NF-κB identification and interaction between NF-κB and DNA.
机译:NF-κB是一种蛋白质复合物,在几乎所有作为转录因子的动物细胞中都可以找到。但是,用于研究NF-κB的常规方法很耗时,并且大多数需要放射性标记。这项研究的目的是开发一种快速的方法,通过使用基于石英晶体微量天平(QCM)的直接特异性结合DNA的生物传感器来研究NF-κB。设计一个特定的DNA探针,并通过5个末端上的巯基进行修饰,使其固定在10 MHz压电石英晶体的镀金表面上,从而构建QCM生物传感器以检测NF-κB。在将探针固定在最佳浓度后,我们绘制了校准曲线,然后通过一系列测试评估了传感器的性能特征。此外,我们使用QCM传感器阵列和ELISA测量了临床样本,以评估QCM传感器。在最佳条件下,压电生物传感器的响应频率在0.25 ng /μX至50 ng /μL范围内线性依赖于NF-kB浓度,批内和批间相对标准偏差(RSD)小于10% 。我们设计的QCM系统具有快速,操作简单,无标签,便宜,灵敏的优点,并且可以作为研究NF-κB的商业化测定方法的有用补充,例如NF-κB结合,NF-κB定量,NF-κB鉴定以及NF-κB与DNA之间的相互作用。

著录项

  • 来源
    《Sensors and Actuators 》 |2010年第1期| P.259-263| 共5页
  • 作者单位

    Department of Laboratory Medicine, Southwest Hospital, Third Military Medical University, Chongqing 400038, PR China;

    rnDepartment of Laboratory Medicine, Southwest Hospital, Third Military Medical University, Chongqing 400038, PR China;

    rnDepartment of Laboratory Medicine, Southwest Hospital, Third Military Medical University, Chongqing 400038, PR China;

    rnDepartment of Laboratory Medicine, Southwest Hospital, Third Military Medical University, Chongqing 400038, PR China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    NF-κB; QCM; biosensor; specific binding DNA;

    机译:NF-κB;QCM;生物传感器特异性结合DNA;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号