...
首页> 外文期刊>Sensors and Actuators >Drift compensation of gas sensor array data by common principal component analysis
【24h】

Drift compensation of gas sensor array data by common principal component analysis

机译:通过通用主成分分析对气体传感器阵列数据进行漂移补偿

获取原文
获取原文并翻译 | 示例

摘要

A new drift compensation method based on common principal component analysis (CPCA) is proposed. The drift variance in data is found as the principal components computed by CPCA. This method finds components that are common for all gasses in feature space. The method is compared in classification task with respect to the other approaches published where the drift direction is estimated through a principal component analysis (PCA) of a reference gas. The proposed new method - employing no specific reference gas, but information from all gases - has shown the same performance as the traditional approach with the best-fitted reference gas. Results are shown with data lasting 7 months including three gases at different concentrations for an array of 17 polymeric sensors.
机译:提出了一种基于公共主成分分析(CPCA)的漂移补偿新方法。发现数据中的漂移方差是CPCA计算的主要成分。此方法查找特征空间中所有气体共有的成分。在分类任务中,与通过参考气体的主成分分析(PCA)估算漂移方向的其他方法进行了比较。所提出的新方法-不使用特定的参考气体,而是从所有气体中获取信息-已显示出与使用最佳拟合参考气体的传统方法相同的性能。结果显示了持续7个月的数据,其中包括针对17种聚合物传感器的三种浓度不同的气体。

著录项

  • 来源
    《Sensors and Actuators 》 |2010年第2期| p.460-465| 共6页
  • 作者单位

    Centre de Recerca en Enginyeria Biomedica, Universitat Politenica de Catalunya, Pau Gargallo 5;

    08028 Barcelona, Spain Centro de Investigation Biomedica en Red en Bioingenieria, Biomateriales y Nanomedkina (CIBER-BBN), Spain;

    rnInstitute for Bioengineering of Catalonia (IBEC), Baldiri Reixac, 13,08028 Barcelona, Spain Centro de Investigation Biomedica en Red en Bioingenieria, Biomateriales y Nanomedkina (CIBER-BBN), Spain Departament d'Electronica, rnUniversitat de Barcelona, Marti i Franques 1,08028 Barcelona, Spain;

    rnProtea Ltd., 11 Mallard Court, Mallard Way, Crewe Business Park, Crewe, Cheshire CWA 6ZQ, UK;

    rnSchool of Chemical Engineering and Analytical Science, The University of Manchester, PO Box 88, Sackville St. Manchester M60 1QD, UK;

    rnCentre de Recerca en Enginyeria Biomedica, Universitat Politenica de Catalunya. Pau Gargallo 5,08028 Barcelona, Spain Centro de Investigation Biomedica en Red en Bioingenieria, Biomateriales y Nanomedkina (CIBER-BBN), Spain;

    rnCentre de Recerca en Enginyeria Biomedica, Universitat Politenica de Catalunya. Pau Gargallo 5,08028 Barcelona, Spain Centro de Investigation Biomedica en Red en Bioingenieria, Biomateriales y Nanomedkina (CIBER-BBN), Spain;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    gas sensor array; drift; common principal component analysis; component correction; electronic nose;

    机译:气体传感器阵列漂移;共同主成分分析;组件校正;电子鼻;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号