Glassy carbon (GC) electrode modified with covalently attached amine-terminated ionic liquid (NH_2-IL) and titanium nitrite nanoparticles (TiNnp) was used as support for immobilization of hemoglobin (Hb) protein. The presence of well-defined and nearly reversible CV peaks with E of -0.03 V (vs. Ag/AgCl) indicated the successful immobilization of Hb on GC/TiNnp/NH_2-IL surface. The surface coverage of Hb immobilized on nanocomposite film (Γ), and heterogeneous electron transfer rate constant (k_s) were 5.12 (±0.05) × 10~(-1) molcm~(-2) and 5.10±0.10s~(-1) respectively, indicating high loading capacity of nanocomposite for direct electron transfer of Hb on the electrode surface. Moreover, the GC/TiNnp/NH_2-IL/Hb electrode revealed excellent electrocatalytic activity toward nitrite reduction. This sensor exhibited fast amperometric response with sensitivity of 0.027 ± 0.009 μA/μM and limit of detection of 0.10 ± 0.010μM at the concentration range up to 2mM. The calculated Michaelis-Menten constant (K_M) of 0.065 (±0.030) mM indicated that Hb immobilized onto the nanocomposite film retained its native activity. The sensor also showed good stability, reproducibility and long lifetime and it was successfully applied for nitrite detection in real samples with obtained satisfactory results.
机译:用共价连接的胺端离子液体(NH_2-IL)和亚硝酸钛纳米粒子(TiNnp)修饰的玻碳(GC)电极被用作固定血红蛋白(Hb)的载体。 E为-0.03 V(vs. Ag / AgCl)时,存在定义明确且几乎可逆的CV峰,表明Hb成功固定在GC / TiNnp / NH_2-IL表面。固定在纳米复合膜上的Hb的表面覆盖率(Γ)和异质电子传递速率常数(k_s)为5.12(±0.05)×10〜(-1)molcm〜(-2)和5.10±0.10s〜(-1 ),表明纳米复合材料对Hb在电极表面上的直接电子转移具有很高的负载能力。此外,GC / TiNnp / NH_2-IL / Hb电极对亚硝酸盐还原具有优异的电催化活性。该传感器在2mM的浓度范围内显示出快速的安培响应,灵敏度为0.027±0.009μA/μM,检测极限为0.10±0.010μM。计算得出的Michaelis-Menten常数(K_M)为0.065(±0.030)mM,表明固定在纳米复合膜上的Hb保留了其天然活性。该传感器还显示出良好的稳定性,可重复性和长寿命,并且已成功用于实际样品中的亚硝酸盐检测,并获得令人满意的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号