首页> 外文期刊>Sensors and Actuators >Fluorescence bioanalytical method for urea determination based on water soluble ZnS quantum dots
【24h】

Fluorescence bioanalytical method for urea determination based on water soluble ZnS quantum dots

机译:基于水溶性ZnS量子点的尿素荧光生物分析方法

获取原文
获取原文并翻译 | 示例
           

摘要

A new bioanalytical method for urea determination by using the immobilized urease on the highly luminescent ZnS quantum dots (QDs), which functioned as the pH fluorescent label has been developed. Bioconjugation of ZnS QDs to urease via amide bond was performed to obtain the ZnS QPs-urease bio-conjugate. Upon enzymatic hydrolysis of urea by the immobilized urease, a pH change to a more alkaline condition has led to the deprotonation of ZnS QDs, and an increase in the fluorescence intensity can be observed. The fluorescence intensity of the urease conjugated ZnS QDs changed linearly with the urea concentrations between 4 x 10~(-9) M and 4 x 10~(-3) M (R~2 =0.992) at pH 6 with a calibration sensitivity of 179.46 intensity/decade. No noticeable influence by the Ca~(2+), Mg~(2+), K~+ and Na~+ ions on the response of the fluorescent pH bioprobe. Urea determination in soil sample by using the urea bioprobe was in good agreement with the standard DMAB (p-dimethylaminobenzaldehyde) UV-vis spectrophotometric method. By employing the strategy of ZnS QDs-urease bioconjugation, the stable covalent link between the two substances has appeared to widen the dynamic range and lower the detection limit for urea compared to free enzyme and QDs in solution for bioassay of urea concentration.
机译:开发了一种新的生物分析方法,该方法通过在高发光ZnS量子点(QDs)上使用固定的脲酶来固定尿素,而ZnS量子点起着pH荧光标记的作用。通过酰胺键将ZnS QDs与尿素酶进行生物共轭以获得ZnS QPs-脲酶生物共轭物。通过固定化脲酶的酶水解,尿素的pH值变化到更碱性的条件导致ZnS QD的去质子化,并且可以观察到荧光强度的增加。在pH值为6时,脲酶结合的ZnS QDs的荧光强度在4×10〜(-9)M和4×10〜(-3)M(R〜2 = 0.992)之间呈线性变化,校准灵敏度为。 179.46强度/十年。 Ca〜(2 +),Mg〜(2 +),K〜+和Na〜+离子对荧光pH探针的响应无明显影响。使用尿素生物探针测定土壤样品中的尿素与标准DMAB(对二甲基氨基苯甲醛)紫外可见分光光度法非常吻合。通过采用ZnS QDs-脲酶生物共轭策略,与游离酶和QDs相比,两种物质之间稳定的共价键似乎扩大了动态范围,并降低了尿素浓度生物测定溶液中尿素的检测限。

著录项

  • 来源
    《Sensors and Actuators》 |2017年第3期|763-769|共7页
  • 作者单位

    School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, SelangorDarul Ehsan, Malaysia,Department of Chemistry, Faculty of Mathematics and Natural Sciences, Syiah Kuala University (USK), Darussalam- Banda Aceh 23111, Indonesia;

    School of Chemical Sciences and Food Technology, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, SelangorDarul Ehsan, Malaysia,Southeast Asia Disaster Prevention Research Initiative (SEADPRI-UKM), LESTARI, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor Darul Ehsan, Malaysia;

    Chemical Technology Program, Faculty of Science and Technology, University Sains Islam Malaysia (USIM), 91800 Nilai, Negeri Sembtlan Darul Khusus, Malaysia;

    Southeast Asia Disaster Prevention Research Initiative (SEADPRI-UKM), LESTARI, Universiti Kebangsaan Malaysia, 43600 UKM Bangi, Selangor Darul Ehsan, Malaysia;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Quantum dots; ZnS; Urea biosensor; Urease immobilization; Fluorescent label;

    机译:量子点;硫化锌;尿素生物传感器固定尿素酶;荧光标签;