In this work, a double-layered microfluidic paper-based device (mu PAD) with multiple colorimetric indicators was presented for the sensitive simultaneous detection of four kinds of small biomolecules, including glucose, uric acid, lactate, and choline in mixture. The double-layered mu PAD were composed of the top detection layer and the bottom auxiliary layer to construct 3D microfluidic channels. The detection zones on the top detection layer were modified with various colorimetric reagents, different kinds of oxidase (glucose oxidase, uricase, lactate oxidase or choline oxidase) and horseradish peroxidase (HRP). The immobilized chromogenic reagents could be oxidized by the generated H2O2 from the specific enzymatic reactions between the oxidases and their corresponding substrates to form different colored products with co-immobilized HRP as catalyst. As a result, four linear calibration curves were obtained for the determination of glucose (0.01-10.0 mmol/L), uric acid (0.01-5.0 mmol/L), lactate (0.04-10.0 mmol/L), and choline (0.04-24.0 mmol/L), respectively. The proposed double-layered mu PAD with multiple colorimetric indicators exhibited good colorimetric performance, effectively improved sensitivity, and extended linear range, which was further applied to the simultaneously determination of glucose, uric acid, lactate, and choline in serum samples.
机译:在这项工作中,提出了一种具有多个比色指示剂的双层微流控纸基设备(mu PAD),用于同时灵敏地检测混合物中的四种小生物分子,包括葡萄糖,尿酸,乳酸和胆碱。双层mu PAD由顶部检测层和底部辅助层组成,以构建3D微流体通道。用各种比色试剂,不同种类的氧化酶(葡萄糖氧化酶,尿酸酶,乳酸氧化酶或胆碱氧化酶)和辣根过氧化物酶(HRP)对顶部检测层上的检测区进行了修饰。固定化的生色试剂可以被氧化酶及其相应底物之间的特定酶促反应生成的H2O2氧化,从而形成以共固定化HRP为催化剂的不同颜色的产物。结果,获得了四个线性校正曲线,用于测定葡萄糖(0.01-10.0 mmol / L),尿酸(0.01-5.0 mmol / L),乳酸(0.04-10.0 mmol / L)和胆碱(0.04-)。 24.0 mmol / L)。所提出的具有多种比色指示剂的双层mu PAD具有良好的比色性能,有效地提高了灵敏度,并扩展了线性范围,从而进一步用于同时测定血清样品中的葡萄糖,尿酸,乳酸和胆碱。

著录项

  • 来源
    《Sensors and Actuators》 |2019年第6期|266-273|共8页
  • 作者单位

    Hefei Univ Technol, Anhui Prov Key Lab Adv Catalyt Mat & React Engn, Sch Chem & Chem Engn, Hefei 230009, Anhui, Peoples R China;

    Hefei Univ Technol, Anhui Prov Key Lab Adv Catalyt Mat & React Engn, Sch Chem & Chem Engn, Hefei 230009, Anhui, Peoples R China;

    Hefei Univ Technol, Anhui Prov Key Lab Adv Catalyt Mat & React Engn, Sch Chem & Chem Engn, Hefei 230009, Anhui, Peoples R China;

    Hefei Univ Technol, Anhui Prov Key Lab Adv Catalyt Mat & React Engn, Sch Chem & Chem Engn, Hefei 230009, Anhui, Peoples R China;

    Hefei Univ Technol, Anhui Prov Key Lab Adv Catalyt Mat & React Engn, Sch Chem & Chem Engn, Hefei 230009, Anhui, Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Microfluidic paper-based device; Glucose; Uric acid; Lactate; Choline;

    机译:微流体纸基设备;葡萄糖;尿酸;乳酸盐;胆碱;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号