摘要

In this work, we for the first time reported a paperfluidic crossing-channel closed-BPE based electrochemiluminescence (P-3C-BPE-ECL) platform where multiple "band"-shaped C-BPEs are situated perpendicular to two parallel channels, and multiplex detection can be achieved in the reporting channel. The paperfluidic devices are easily fabricated by wax and carbon ink-based screen-printing processes. Under optimized conditions, the P-3C-BPE-ECL is applied to the quantitative analysis of hydrogen peroxide (H2O2) and glucose, with corresponding linear ranges of 0.075-10 mM and 0.08-5 mM, and corresponding detection limits of 0.041 mM and 0.03 mM. To our knowledge, this is the first demonstration of paperfluidic C-BPE-ECL method for glucose determination. Based on its acceptable selectivity, the P-3C-BPE-ECL method is used for measurements of glucose in four complex samples (human serum and urine, wine, and glucose injection) and is compared with the traditional methods. The results indicate a good agreement and prove the reliability and accuracy of the proposed platform. Importantly, the proposed method is demonstrated to have the potential for duplex detection of glucose and uric acid, which intensively matches the requirement of those patients simultaneously suffering from diabetes and gout. Therefore, we believe that the P-3C-BPE-ECL could provide a new platform for wide biochemical applications. (C) 2018 Elsevier B.V. All rights reserved.
机译:在这项工作中,我们首次报道了一种基于纸流交叉通道封闭BPE的电化学发光(P-3C-BPE-ECL)平台,其中多个“带”形C-BPE垂直于两个平行通道放置,在报告通道中可以实现多路复用检测。通过基于蜡和碳墨水的丝网印刷工艺可以轻松地制造纸质流体设备。在最佳条件下,P-3C-BPE-ECL用于定量分析过氧化氢(H2O2)和葡萄糖,线性范围分别为0.075-10 mM和0.08-5 mM,相应的检出限为0.041 mM和0.03毫米据我们所知,这是纸流式C-BPE-ECL方法用于葡萄糖测定的首次演示。基于其可接受的选择性,P-3C-BPE-ECL方法用于测量四个复杂样品(人血清和尿液,葡萄酒和葡萄糖注射液)中的葡萄糖,并与传统方法进行了比较。结果表明了良好的一致性,并证明了所提出平台的可靠性和准确性。重要的是,事实证明所提出的方法具有双重检测葡萄糖和尿酸的潜力,这与那些同时患有糖尿病和痛风的患者的需求高度匹配。因此,我们相信P-3C-BPE-ECL可以为广泛的生化应用提供新的平台。 (C)2018 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号