An array of 64 silicon surface‐barrier diodes on a circular arc view Tokamak Fusion Test Reactor (TFTR) plasmas through a slot aperture to provide poloidal imaging of x‐ray emission in the 200 eV–15 keV range. Information is inferred on magnetohydrodynamic (MHD) instabilities, disruptions, radiation, impurity transport, electron temperature, and electron thermal conductivity. Spatial resolution is 2.5 cm. Movable absorber foil arrays provide energy selection. Preamplifier–amplifier pairs have gains of 0.05–100 V/μA. Two outputs are provided with (1) 40‐, 80‐, and 300‐Hz and (2) 40‐, 80‐, and 600‐kHz filtering. The signals are digitized at rates up to 500 kHz and stored in 128K (total system) memory. Foils, gains, and filters are selectable from the control room by a computer.
机译:圆弧视图上的64个硅表面势垒二极管阵列通过一个缝隙孔观察托卡马克聚变测试反应堆(TFTR)等离子体,以提供200 eV–15 keV范围内x射线发射的倍性成像。可以推断出有关磁流体动力学(MHD)的不稳定性,破坏,辐射,杂质传输,电子温度和电子热导率的信息。空间分辨率为2.5厘米。可移动的吸收器箔片阵列提供能量选择。前置放大器-放大器对的增益为0.05–100 V /μA。提供两个输出,分别具有(1)40、80和300Hz,以及(2)40、80和600kHz滤波。信号以高达500 kHz的速率数字化,并存储在128K(整个系统)存储器中。可以从控制室中通过计算机选择箔,增益和过滤器。