We present a parallel multiplex laser feedback interferometer based on spatial multiplexing which avoids the signal crosstalk in the former feedback interferometer. The interferometer outputs two close parallel laser beams, whose frequencies are shifted by two acousto-optic modulators by 2Ω simultaneously. A static reference mirror is inserted into one of the optical paths as the reference optical path. The other beam impinges on the target as the measurement optical path. Phase variations of the two feedback laser beams are simultaneously measured through heterodyne demodulation with two different detectors. Their subtraction accurately reflects the target displacement. Under typical room conditions, experimental results show a resolution of 1.6 nm and accuracy of 7.8 nm within the range of 100 μm.
机译:我们提出了一种基于空间复用的并行复用激光反馈干涉仪,它避免了前者反馈干涉仪中的信号串扰。干涉仪输出两束近乎平行的激光束,其频率被两个声光调制器同时偏移2Ω。将静态参考镜插入到光路之一中作为参考光路。另一束作为测量光路射在目标上。通过使用两个不同的检测器进行外差解调,可以同时测量两个反馈激光束的相位变化。它们的减法准确反映了目标位移。在典型的室温条件下,实验结果表明,在100μm范围内,分辨率为1.6 nm,精度为7.8 nm。