首页> 外文期刊>Research journal of applied science, engineering and technology >Determination and Comparison of Absorbed dose of Ovaries and Uterus in Heart Scan from TC-99 m, by Three Methods: TLD Measurement, MCNP Simulation and MIRD Calculation and Estimation of its Risks
【24h】

Determination and Comparison of Absorbed dose of Ovaries and Uterus in Heart Scan from TC-99 m, by Three Methods: TLD Measurement, MCNP Simulation and MIRD Calculation and Estimation of its Risks

机译:通过三种方法:TLD测量,MCNP模拟和MIRD计算及其风险评估,确定和比较TC-99 m心脏扫描中卵巢和子宫的吸收剂量

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Relation to high absorption fraction of Tc sestamibi by kidneys in heart scan and these organs are near to generation organs (Ovaries and uterus). Urinary system (kidneys and urinary bladder) are specified as sources organs. The main object of this study is to determine the absorbed dose in these critical organs, we have set amount of absorbed fraction radiopharmaceutical in position of kidneys and Urinary bladder in Rando phantom in form of elliptical surfaces, men absorbed dose to ovaries and uterus measured by TLD-100 that had set at position of these organs in Rando phantom. Results from ORNL phantom MIRD calculation TLD measurement and Rando phantom simulation (MCNP) are comprised. The absorbed dose to uterus and ovaries from urinary system for Rest are 0.139, 0.242 μSv/MBq and for Stress state are 0.105, 0.182 μSv/MBq, respectively.
机译:肾脏在心脏扫描中与Tc sestamibi的高吸收率有关,这些器官靠近产生器官(卵巢和子宫)。泌尿系统(肾脏和膀胱)被指定为来源器官。这项研究的主要目的是确定这些关键器官的吸收剂量,我们以椭圆形表面的形式在兰多体模中的肾脏和膀胱位置设置了放射性药物的吸收分数,男性对卵巢和子宫的吸收剂量通过已在兰多幻影中的这些器官位置设置了TLD-100。包括来自ORNL体模MIRD计算TLD测量和Rando体模仿真(MCNP)的结果。泌尿系统对泌尿系统子宫和卵巢的吸收剂量分别为0.139、0.242μSv/ MBq和应激状态,分别为0.105、0.182μSv/ MBq。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号