摘要

This study introduces a method tor voltage sag source location based on Hilbert Huang transformed monitored current signal. Unlike the traditional method, the proposed method first transforms the recorded current during the sag event to obtain frequency-time plot (Hilbert spectra) and IMF plot before the location of voltage sag source is determined. Then based on the change in frequency and IMF the relative location of voltage sag source is I obtained. The effectiveness of the proposed method has been verified through simulation on 20 bus system and by comparing with an existing S-Transform based method. The results show that the presented method can determine the location of voltage sag source correctly.
机译:本研究介绍了一种基于希尔伯特·黄(Hilbert Huang)变换监测电流信号的电压暂降源定位方法。与传统方法不同,所提出的方法在确定电压骤降源的位置之前,首先在骤降事件期间转换记录的电流以获得频率-时间图(希尔伯特频谱)和IMF图。然后根据频率和IMF的变化,得出电压骤降源的相对位置。通过在20总线系统上进行仿真,并与现有的基于S-Transform的方法进行比较,验证了该方法的有效性。结果表明,该方法能够正确确定电压暂降源的位置。