首页> 外文期刊>Reliability Engineering & System Safety >Availability assessment of a two-unit stand-by pumping system
【24h】

Availability assessment of a two-unit stand-by pumping system

机译:两单元备用泵系统的可用性评估

获取原文
获取原文并翻译 | 示例
       

摘要

The paper aims at assessing the availability of a critical pumping system of the Crude Distillation Unit of a refinery with recourse to the Markovian model. Actual field data on failure and the repair times have been collected and analyzed by fitting exponential distribution. Also A simulation model has been developed for assessing the system availability. The availabilities based on both the analytical and the Simulation models have been compared. The simulation model has been used for predicting system availability for varying failure and The repair rates. The repair strategies for the increasing failure rate in order to attain the desired availability have also been discussed in the Paper.
机译:本文旨在评估利用马尔可夫模型的炼油厂原油蒸馏装置关键泵系统的可用性。已通过拟合指数分布收集并分析了有关故障和维修时间的实际现场数据。还开发了一个仿真模型来评估系统可用性。比较了基于分析模型和仿真模型的可用性。仿真模型已用于预测各种故障和修复率的系统可用性。该文件中还讨论了提高故障率以达到所需可用性的维修策略。