首页> 外文期刊>Radiation Protection Dosimetry >VARIATION IN INDOOR THORON LEVELS IN MEXICO CITY DWELLINGS
【24h】

VARIATION IN INDOOR THORON LEVELS IN MEXICO CITY DWELLINGS

机译:墨西哥城住宅中室内泰隆水平的变化

获取原文
获取原文并翻译 | 示例

摘要

This paper presents the results obtained for thoron concentration in 50 single-family dwellings in normal occupancy conditions (open house conditions), measured by a passive electret system (type E-PERM, SSTB configuration) in a 2001-2002 monitoring survey in the Metropolitan Zone of Mexico City. The results show the general log-normal distribution of integrated indoor thoron concentration with annual arithmetic and geometric means of 82 and 55 Bq m~(-3), respectively, with ranges from 8 to 234 Bq m~(-3) higher than world average of 3 Bq m~(-3). The seasonal variation shows the minimum mean values in the summer season that were 35% lower than in autumn.
机译:本文介绍了2001年至2002年在大都市进行的无源驻极体系统(E-PERM型,SSTB型)在正常居住条件(开房条件)下50个单户住宅中的浓度结果。墨西哥城区。结果表明,室内年ron综合浓度的一般对数正态分布分别为82和55 Bq m〜(-3),年均算术和几何平均数为8-234 Bq m〜(-3)。平均3 Bq m〜(-3)。季节变化显示,夏季的最低平均值比秋季低35%。

著录项

  • 来源
    《Radiation Protection Dosimetry 》 |2004年第1期| p.111-113| 共3页
  • 作者单位

    National University of Mexico, Faculty of Chemistry, Building D, Ciudad Universitaria, 04510, Mexico City, Mexico;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 TL72;
  • 关键词