首页> 外文期刊>Radiation Protection Dosimetry >EVALUATION OF THE DOSE RATE DISTRIBUTION FOR AN AIR-TYPE ~(60)CO IRRADIATION FACILITY
【24h】

EVALUATION OF THE DOSE RATE DISTRIBUTION FOR AN AIR-TYPE ~(60)CO IRRADIATION FACILITY

机译:空气〜(60)CO辐照装置剂量率分布的评估

获取原文
获取原文并翻译 | 示例

摘要

The dose rate distributions in the 29,000-Ci ~(60)Co irradiation facility in National Tsing Hua University were investigated by measurements and calculations. The dose rate measurements were performed using radiochromic dye films and an Exradin A2 ion chamber mounted on a PC-controlled motorised vertical translation stage. The calculations were made by using the three-dimensional point kernel code QAD-CGGP with detailed source composition and geometry modelling. The scattered gamma rays from the walls of the irradiation cell were also evaluated by using the Monte Carlo code MCNP.
机译:通过测量和计算研究了国立清华大学29,000-Ci〜(60)Co辐照设备中的剂量率分布。剂量率测量是使用放射致变色染料膜和安装在PC控制的电动垂直平移台上的Exradin A2离子室进行的。通过使用具有详细源组成和几何建模的三维点内核代码QAD-CGGP进行计算。还使用蒙特卡罗代码MCNP对来自辐照室壁的散射伽马射线进行了评估。

著录项

  • 来源
    《Radiation Protection Dosimetry 》 |2005年第4期| p.352-358| 共7页
  • 作者单位

    Department of Engineering and System Science, National Tsing Hua University, Hsinchu 300, Taiwan, Republic of China;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 计量学 ;
  • 关键词

相似文献