This paper aims at comparing dosimetric assessments performed with three Monte Carlo codes: EGS4, MCNP4c2 and MCNPX2.5e, using a realistic voxel phantom, namely the Zubal phantom, in two configurations of exposure. The first one deals with an external irradiation corresponding to the example of a radiological accident. The results are obtained using the EGS4 and the MCNP4c2 codes and expressed in terms of the mean absorbed dose (in Gy per source particle) for brain, lungs, liver and spleen. The second one deals with an internal exposure corresponding to the treatment of a medullary thyroid cancer by ~(131)I-labelled radiopharmaceutical. The results are obtained by EGS4 and MCNPX2.5e and compared in terms of S-values (expressed in mGy per kBq and per hour) for liver, kidney, whole body and thyroid. The results of these two studies are presented and differences between the codes are analysed and discussed.
机译:本文旨在比较使用两种曝光的真实体素体模(即Zubal体模)对三种蒙特卡洛代码EGS4,MCNP4c2和MCNPX2.5e进行的剂量学评估。第一个处理对应于放射事故示例的外部辐射。使用EGS4和MCNP4c2代码获得结果,并以脑,肺,肝和脾的平均吸收剂量(每个源颗粒的Gy)表示。第二种方法涉及内部暴露,该内部暴露对应于通过〜(131)I标记的放射性药物治疗甲状腺髓样癌。通过EGS4和MCNPX2.5e获得结果,并以肝脏,肾脏,全身和甲状腺的S值(以mGy / kBq和每小时表示)进行比较。介绍了这两项研究的结果,并对代码之间的差异进行了分析和讨论。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号