首页> 外文期刊>Radiation Protection Dosimetry >IAEA REGIONAL INTERCOMPARISON OF IN VIVO MEASUREMENTS OF ~(131)I IN THE THYROID: THE LATIN AMERICAN AND CARIBBEAN EXPERIENCE
【24h】

IAEA REGIONAL INTERCOMPARISON OF IN VIVO MEASUREMENTS OF ~(131)I IN THE THYROID: THE LATIN AMERICAN AND CARIBBEAN EXPERIENCE

机译:IAEA甲状腺中〜(131)I体内测量的区域比对:拉丁美洲和加勒比海经验

获取原文
获取原文并翻译 | 示例
           

摘要

An in vivo intercomparison exercise, organised in the scope of the IAEA Regional Latin American (RLA) Project 9066, was carried out in 2009 aimed to harmonise measurement procedures on the measurement of ~(131)I in the thyroid among Latin American and Caribbean countries. The exercise consisted in the measurement of an anthropomorphic thyroid phantom spiked with a certified source of ~(133)Ba. The phantom was supplied by the In; Vivo Monitoring Laboratory of Institute for Radiation Protection and Dosimetry (IRD) to 17 Institutions from 12 countries of the regions. Among these, 13 Institutions from 10 countries returned their measurement results as well as a standard report form containing detailed information about their respective counting facilities. All participants reported activities within an acceptable range, considering American National Standard Institute (ANSI) limits. Uncertainties varied from 0.04 to 12.9 %. Although results show that the general performance was acceptable in terms of accuracy, the need for additional action towards the standardisation of uncertainty estimation in this type of measurement in the region should be highlighted.
机译:2009年在国际原子能机构拉美地区(RLA)项目9066的范围内组织了一次体内比对活动,旨在协调拉丁美洲和加勒比国家甲状腺中〜(131)I的测量程序。这项运动包括测量掺有〜(133)Ba认证来源的拟人化甲状腺模型。幻影由In提供;辐射防护与剂量学研究所(IRD)的体内监测实验室,来自该地区12个国家的17个机构。其中,来自10个国家的13个机构退还了其测量结果以及一份标准报告表,其中包含有关各自计数工具的详细信息。考虑到美国国家标准协会(ANSI)的限制,所有参与者的活动均在可接受的范围内。不确定度从0.04%到12.9%不等。尽管结果表明总体性能在准确性方面是可以接受的,但应该强调需要采取其他措施来使该区域此类测量中的不确定性估计标准化。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2011年第4期|p.291-294|共4页
  • 作者单位

    Institute de Radioprotecao e Dosimetria-IRD, Av Salvador Allende, Rio de Janeiro, CEP 22780-160, Brazil;

    Institute de Radioprotecao e Dosimetria-IRD, Av Salvador Allende, Rio de Janeiro, CEP 22780-160, Brazil;

    Institute de Radioprotecao e Dosimetria-IRD, Av Salvador Allende, Rio de Janeiro, CEP 22780-160, Brazil;

    Institute de Radioprotecao e Dosimetria-IRD, Av Salvador Allende, Rio de Janeiro, CEP 22780-160, Brazil;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng