SPECTRA OF LINEAR ENERGY TRANSFER AND OTHER DOSIMETRY CHARACTERISTICS AS MEASURED IN C290 MeV MONO AND SOBP ION BEAMS AT HIMAC-BIO (MRS, JAPAN) WITH DIFFERENT DETECTORS

机译:在具有不同检测器的HIMAC-BIO(日本MRS)的C290 MeV / n单离子和SOBP离子束中测量的线性能量传递和其他剂量特征

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Active mobile dosimetry unit (Liulin), passive plastic nuclear track detectors (PNTD) and thermoluminescent detectors (TLD) were exposed in a C290 MeV beam at HIMAC-BIO (MRS, Japan). Two different types of beam configuration were used-monoenergetic beam (MONO) and spread-out Bragg peak (SOBP); the detectors were placed at several depths from the entrance up to the depths behind the Bragg peak. Relative response of TLDs in beams has been studied as a function of the depth, and it was re-proved that it can depend on the linear energy transfer (LET). Liulin measures energy deposition in Si; the spectra of energy deposited in Si can be transformed to the spectra of lineal energy or LET. PNTDs are able to determine the LET of registered particles directly. The limitation of both methods is in the range in which they can determine the LET-Liulin is able to measure perpendicularly incident charged particles up to ~35 keV/μn (in water), PNTD can measure from ~7 to 400 keV/μn, independently of the registration angle. The results from both methods are compared and combined for both beams' configuration, and a good agreement is observed.
机译:有源移动剂量测定仪(Liulin),无源塑料核径迹检测器(PNTD)和热发光检测器(TLD)在HIMAC-BIO(日本,MRS)的C290 MeV / n光束中曝光。使用了两种不同类型的光束配置:单能光束(MONO)和扩展布拉格峰(SOBP)。从入口到布拉格峰后面的深度,探测器被放置在几个深度处。研究了光束中TLD的相对响应与深度的关系,并再次证明了它可以取决于线性能量传递(LET)。柳林测量硅中的能量沉积;沉积在Si中的能量光谱可以转换为线性能量或LET的光谱。 PNTD能够直接确定已注册粒子的LET。两种方法的局限性在于它们无法确定LET-Liulin能够测量垂直入射的带电粒子(水中)高达〜35 keV /μn,PNTD的测量范围约为7至400 keV /μn,与配准角无关。比较了两种方法的结果,并结合了两种光束的配置,观察到了很好的一致性。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2011年第4期|p.519-522|共4页
  • 作者单位

    Department of Radiation Dosimetry, Nuclear Physics Institute, Czech Academy of Sciences, Na Truhlarce 39/64, 18086 Praha 8, Czech Republic;

    Department of Radiation Dosimetry, Nuclear Physics Institute, Czech Academy of Sciences, Na Truhlarce 39/64, 18086 Praha 8, Czech Republic;

    Department of Radiation Dosimetry, Nuclear Physics Institute, Czech Academy of Sciences, Na Truhlarce 39/64, 18086 Praha 8, Czech Republic;

    Department of Radiation Dosimetry, Nuclear Physics Institute, Czech Academy of Sciences, Na Truhlarce 39/64, 18086 Praha 8, Czech Republic;

    Department of Radiation Dosimetry, Nuclear Physics Institute, Czech Academy of Sciences, Na Truhlarce 39/64, 18086 Praha 8, Czech Republic;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号