首页> 外文期刊>Radiation Protection Dosimetry >ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY
【24h】

ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY

机译:计算机断层扫描中中心切片的特定剂量剂量估算的准确性

获取原文
获取原文并翻译 | 示例
           

摘要

To evaluate the accuracy of size-specific dose estimate (SSDE) calculation from center slice with water-equivalent diameter (Dw) and effective diameter (Deff). A total of 1812 CT exams (1583 adult and 229 pediatric) were included in this retrospective study. Dw and Deff were automatically calculated for all slices of each scan. SSDEs were calculated with two methods: (1) from the center slice; and (2) from all slices of the volume, which was regarded as the reference standard. Impact of patient weight, height and body mass index (BMI) on SSDE accuracy was assessed. The mean difference between overall SSDE and the center slice approach ranged from 2.0 ± 1.7% (range: 0-15.5%) for pediatric chest to 5.0 ± 3.2% (0-17.2%) for adult chest CT. Accuracy of the center slice SSDE approach correlated with patient size (BMI: r = 0.15-0.43; weight r = 0.26-0.49) which led to SSDE overestimation in small and underestimation in large patients. SSDE calculation using the center slice leads to an error of 2-5%; however, SSDE is underestimated in large patients and overestimation in small patients.
机译:为了评估中心切片具有水当量直径(Dw)和有效直径(Deff)时特定尺寸剂量估计(SSDE)计算的准确性。这项回顾性研究共包括1812项CT检查(1583名成人和229名儿科)。 Dw和Deff是针对每次扫描的所有切片自动计算的。 SSDE通过两种方法计算:(1)从中心切片开始; (2)从所有体积切片中将其视为参考标准。评估了患者体重,身高和体重指数(BMI)对SSDE准确性的影响。总体SSDE与中心切片法之间的平均差值范围从小儿胸部的2.0±1.7%(范围:0-15.5%)到成人胸部CT的5.0±3.2%(0-17.2%)。中心切片SSDE方法的准确性与患者人数相关(BMI:r = 0.15-0.43;体重r = 0.26-0.49),这导致小患者SSDE高估而大患者低估。使用中心切片进行SSDE计算会导致2-5%的误差;然而,在大患者中SSDE被低估了,在小患者中被高估了。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2018年第1期|8-19|共12页
  • 作者单位

    Department of Diagnostic and Interventional Radiology, Medical Faculty, University Duesseldorf, Moorenstrasse 5, 40 225 Duesseldorf, Germany;

    Department of Diagnostic and Interventional Radiology, Medical Faculty, University Duesseldorf, Moorenstrasse 5, 40 225 Duesseldorf, Germany;

    Department of Diagnostic and Interventional Radiology, Medical Faculty, University Duesseldorf, Moorenstrasse 5, 40 225 Duesseldorf, Germany;

    Department of Diagnostic and Interventional Radiology, Medical Faculty, University Duesseldorf, Moorenstrasse 5, 40 225 Duesseldorf, Germany;

    Department of Diagnostic and Interventional Radiology, Medical Faculty, University Duesseldorf, Moorenstrasse 5, 40 225 Duesseldorf, Germany;

    Department of Diagnostic and Interventional Radiology, Medical Faculty, University Duesseldorf, Moorenstrasse 5, 40 225 Duesseldorf, Germany;

    Department of Diagnostic and Interventional Radiology, Medical Faculty, University Duesseldorf, Moorenstrasse 5, 40 225 Duesseldorf, Germany;

    Department of Diagnostic and Interventional Radiology, Medical Faculty, University Duesseldorf, Moorenstrasse 5, 40 225 Duesseldorf, Germany;

    Department of Diagnostic and Interventional Radiology, Medical Faculty, University Duesseldorf, Moorenstrasse 5, 40 225 Duesseldorf, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号